Abstract

Endocytoscopy is an optical biopsy technique which uses a miniaturized camera to capture white light microscopy images through an endoscope. We have developed an alternative design that instead relays images to an external camera via a coherent fiber bundle. In this paper we characterize the device and demonstrate microscopy of porcine tissue ex vivo. One advantage of our approach is the ease with which other bundle-compatible imaging modalities can be deployed simultaneously. We show this by acquiring quasi-simultaneous endocytoscopy and fluorescence confocal endomicroscopy images through a single fiber bundle. This opens up possibilities for multi-modal endomicroscopy, combining white light and fluorescence imaging.

Citing Articles

Near-Infrared Fluorescence Imaging Sensor with Laser Diffuser for Visualizing Photoimmunotherapy Effects under Endoscopy.

Takamatsu T, Tanaka H, Yano T Sensors (Basel). 2024; 24(5).

PMID: 38475023 PMC: 10934203. DOI: 10.3390/s24051487.


Unsupervised full-color cellular image reconstruction through disordered optical fiber.

Hu X, Zhao J, Enrique Antonio-Lopez J, Amezcua Correa R, Schulzgen A Light Sci Appl. 2023; 12(1):125.

PMID: 37221183 PMC: 10206102. DOI: 10.1038/s41377-023-01183-6.


Large field-of-view short-wave infrared metalens for scanning fiber endoscopy.

Xie N, Carson M, Froch J, Majumdar A, Seibel E, Bohringer K J Biomed Opt. 2023; 28(9):094802.

PMID: 36911164 PMC: 9997523. DOI: 10.1117/1.JBO.28.9.094802.


Fiber Bundle Image Reconstruction Using Convolutional Neural Networks and Bundle Rotation in Endomicroscopy.

Eadie M, Liao J, Ageeli W, Nabi G, Krstajic N Sensors (Basel). 2023; 23(5).

PMID: 36904673 PMC: 10007631. DOI: 10.3390/s23052469.


Establishment of a guided, in vivo, multi-channel, abdominal, tissue imaging approach.

Bahlmann J, Madrahimov N, Daniel F, Theidel D, DeTemple D, Buettner M Sci Rep. 2020; 10(1):9224.

PMID: 32513950 PMC: 7280182. DOI: 10.1038/s41598-020-65950-w.


References
1.
Regunathan R, Woo J, Pierce M, Polydorides A, Raoufi M, Roayaie S . Feasibility and preliminary accuracy of high-resolution imaging of the liver and pancreas using FNA compatible microendoscopy (with video). Gastrointest Endosc. 2012; 76(2):293-300. PMC: 3904224. DOI: 10.1016/j.gie.2012.04.445. View

2.
Neumann H, Fuchs F, Vieth M, Atreya R, Siebler J, Kiesslich R . Review article: in vivo imaging by endocytoscopy. Aliment Pharmacol Ther. 2011; 33(11):1183-93. DOI: 10.1111/j.1365-2036.2011.04647.x. View

3.
Liu X, Huang Y, Kang J . Dark-field illuminated reflectance fiber bundle endoscopic microscope. J Biomed Opt. 2011; 16(4):046003. PMC: 3094130. DOI: 10.1117/1.3560298. View

4.
Tearney G, Brezinski M, Bouma B, Boppart S, Pitris C, Southern J . In vivo endoscopic optical biopsy with optical coherence tomography. Science. 1997; 276(5321):2037-9. DOI: 10.1126/science.276.5321.2037. View

5.
Makhlouf H, Gmitro A, Tanbakuchi A, Udovich J, Rouse A . Multispectral confocal microendoscope for in vivo and in situ imaging. J Biomed Opt. 2008; 13(4):044016. PMC: 4822696. DOI: 10.1117/1.2950313. View