» Articles » PMID: 24400100

Non-enhanced MR Imaging of Cerebral Aneurysms: 7 Tesla Versus 1.5 Tesla

Overview
Journal PLoS One
Date 2014 Jan 9
PMID 24400100
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To prospectively evaluate 7 Tesla time-of-flight (TOF) magnetic resonance angiography (MRA) in comparison to 1.5 Tesla TOF MRA and 7 Tesla non-contrast enhanced magnetization-prepared rapid acquisition gradient-echo (MPRAGE) for delineation of unruptured intracranial aneurysms (UIA).

Material And Methods: Sixteen neurosurgical patients (male n = 5, female n = 11) with single or multiple UIA were enrolled in this trial. All patients were accordingly examined at 7 Tesla and 1.5 Tesla MRI utilizing dedicated head coils. The following sequences were obtained: 7 Tesla TOF MRA, 1.5 Tesla TOF MRA and 7 Tesla non-contrast enhanced MPRAGE. Image analysis was performed by two radiologists with regard to delineation of aneurysm features (dome, neck, parent vessel), presence of artifacts, vessel-tissue-contrast and overall image quality. Interobserver accordance and intermethod comparisons were calculated by kappa coefficient and Lin's concordance correlation coefficient.

Results: A total of 20 intracranial aneurysms were detected in 16 patients, with two patients showing multiple aneurysms (n = 2, n = 4). Out of 20 intracranial aneurysms, 14 aneurysms were located in the anterior circulation and 6 aneurysms in the posterior circulation. 7 Tesla MPRAGE imaging was superior over 1.5 and 7 Tesla TOF MRA in the assessment of all considered aneurysm and image quality features (e.g. image quality: mean MPRAGE7T: 5.0; mean TOF7T: 4.3; mean TOF1.5T: 4.3). Ratings for 7 Tesla TOF MRA were equal or higher over 1.5 Tesla TOF MRA for all assessed features except for artifact delineation (mean TOF7T: 4.3; mean TOF1.5T 4.4). Interobserver accordance was good to excellent for most ratings.

Conclusion: 7 Tesla MPRAGE imaging demonstrated its superiority in the detection and assessment of UIA as well as overall imaging features, offering excellent interobserver accordance and highest scores for all ratings. Hence, it may bear the potential to serve as a high-quality diagnostic tool for pretherapeutic assessment and follow-up of untreated UIA.

Citing Articles

Use of a Commercial 7-T MRI Scanner for Clinical Brain Imaging: Indications, Protocols, Challenges, and Solutions-A Single-Center Experience.

Ozutemiz C, White M, Elvendahl W, Eryaman Y, Marjanska M, Metzger G AJR Am J Roentgenol. 2023; 221(6):788-804.

PMID: 37377363 PMC: 10825876. DOI: 10.2214/AJR.23.29342.


Diagnosis of Small Unruptured Intracranial Aneurysms : Comparison of 7 T versus 3 T MRI.

Radojewski P, Dobrocky T, Branca M, Almiri W, Correia M, Raabe A Clin Neuroradiol. 2023; 34(1):45-49.

PMID: 37000197 PMC: 10881608. DOI: 10.1007/s00062-023-01282-2.


Clinical application of ultra-high resolution compressed sensing time-of-flight MR angiography at 7T to detect small vessel pathology.

Lakhani D, Zhou X, Tao S, Westerhold E, Eidelman B, Sandhu S Neuroradiol J. 2022; 36(3):335-340.

PMID: 36173305 PMC: 10268099. DOI: 10.1177/19714009221129576.


Assessment of Heating on Titanium Alloy Cerebral Aneurysm Clips during 7T MRI.

Tsutsui S, Matsuda T, Takeda K, Sasaki M, Kubo Y, Setta K AJNR Am J Neuroradiol. 2022; 43(7):972-977.

PMID: 35738672 PMC: 9262056. DOI: 10.3174/ajnr.A7561.


Imaging Modalities for Intracranial Aneurysm: More Than Meets the Eye.

Maupu C, Lebas H, Boulaftali Y Front Cardiovasc Med. 2022; 9:793072.

PMID: 35242823 PMC: 8885801. DOI: 10.3389/fcvm.2022.793072.


References
1.
Nowinski W, Puspitasaari F, Volkau I, Marchenko Y, Knopp M . Comparison of magnetic resonance angiography scans on 1.5, 3, and 7 Tesla units: a quantitative study of 3-dimensional cerebrovasculature. J Neuroimaging. 2011; 23(1):86-95. DOI: 10.1111/j.1552-6569.2011.00597.x. View

2.
Ferre J, Carsin-Nicol B, Morandi X, Carsin M, de Kersaint-Gilly A, Gauvrit J . Time-of-flight MR angiography at 3T versus digital subtraction angiography in the imaging follow-up of 51 intracranial aneurysms treated with coils. Eur J Radiol. 2008; 72(3):365-9. DOI: 10.1016/j.ejrad.2008.08.005. View

3.
Gibbs G, Huston 3rd J, Bernstein M, Riederer S, Brown Jr R . Improved image quality of intracranial aneurysms: 3.0-T versus 1.5-T time-of-flight MR angiography. AJNR Am J Neuroradiol. 2004; 25(1):84-7. PMC: 7974183. View

4.
Fogelholm R, Hernesniemi J, Vapalahti M . Impact of early surgery on outcome after aneurysmal subarachnoid hemorrhage. A population-based study. Stroke. 1993; 24(11):1649-54. DOI: 10.1161/01.str.24.11.1649. View

5.
Monninghoff C, Maderwald S, Theysohn J, Kraff O, Ladd S, Ladd M . Evaluation of intracranial aneurysms with 7 T versus 1.5 T time-of-flight MR angiography - initial experience. Rofo. 2008; 181(1):16-23. DOI: 10.1055/s-2008-1027863. View