Robot-assisted Therapy in Stroke Rehabilitation

Overview
Journal J Stroke
Date 2014 Jan 8
PMID 24396811
Citations 114
Authors
Affiliations
Soon will be listed here.
Abstract

Research into rehabilitation robotics has grown rapidly and the number of therapeutic rehabilitation robots has expanded dramatically during the last two decades. Robotic rehabilitation therapy can deliver high-dosage and high-intensity training, making it useful for patients with motor disorders caused by stroke or spinal cord disease. Robotic devices used for motor rehabilitation include end-effector and exoskeleton types; herein, we review the clinical use of both types. One application of robot-assisted therapy is improvement of gait function in patients with stroke. Both end-effector and the exoskeleton devices have proven to be effective complements to conventional physiotherapy in patients with subacute stroke, but there is no clear evidence that robotic gait training is superior to conventional physiotherapy in patients with chronic stroke or when delivered alone. In another application, upper limb motor function training in patients recovering from stroke, robot-assisted therapy was comparable or superior to conventional therapy in patients with subacute stroke. With end-effector devices, the intensity of therapy was the most important determinant of upper limb motor recovery. However, there is insufficient evidence for the use of exoskeleton devices for upper limb motor function in patients with stroke. For rehabilitation of hand motor function, either end-effector and exoskeleton devices showed similar or additive effects relative to conventional therapy in patients with chronic stroke. The present evidence supports the use of robot-assisted therapy for improving motor function in stroke patients as an additional therapeutic intervention in combination with the conventional rehabilitation therapies. Nevertheless, there will be substantial opportunities for technical development in near future.

Citing Articles

A Personalized Multimodal BCI-Soft Robotics System for Rehabilitating Upper Limb Function in Chronic Stroke Patients.

Premchand B, Zhang Z, Ang K, Yu J, Tan I, Lam J Biomimetics (Basel). 2025; 10(2).

PMID: 39997117 PMC: 11852476. DOI: 10.3390/biomimetics10020094.


NeuroFlex: Feasibility of EEG-Based Motor Imagery Control of a Soft Glove for Hand Rehabilitation.

Zare S, Beaber S, Sun Y Sensors (Basel). 2025; 25(3).

PMID: 39943246 PMC: 11820135. DOI: 10.3390/s25030610.


Emerging scaffold- and cellular-based strategies for brain tissue regeneration and imaging.

Collins M, Zamboni F, Serafin A, Escobar A, Stepanian R, Culebras M In Vitro Model. 2025; 1(2):129-150.

PMID: 39872806 PMC: 11756503. DOI: 10.1007/s44164-022-00013-0.


Robot-assisted gait training in stroke.

Koldas Dogan S Turk J Phys Med Rehabil. 2024; 70(3):293-299.

PMID: 39679124 PMC: 11639496. DOI: 10.5606/tftrd.2024.15681.


Design and control of a low-cost non-backdrivable end-effector upper limb rehabilitation device.

Li F, Guo Y, Xu W, Zhang W, Zhao F, Wang B Front Rehabil Sci. 2024; 5:1469491.

PMID: 39678125 PMC: 11638233. DOI: 10.3389/fresc.2024.1469491.


References
1.
Lum P, Burgar C, Shor P, Majmundar M, Van der Loos M . Robot-assisted movement training compared with conventional therapy techniques for the rehabilitation of upper-limb motor function after stroke. Arch Phys Med Rehabil. 2002; 83(7):952-9. DOI: 10.1053/apmr.2001.33101. View

2.
Husemann B, Muller F, Krewer C, Heller S, Koenig E . Effects of locomotion training with assistance of a robot-driven gait orthosis in hemiparetic patients after stroke: a randomized controlled pilot study. Stroke. 2007; 38(2):349-54. DOI: 10.1161/01.STR.0000254607.48765.cb. View

3.
Burgar C, Lum P, Scremin A, Garber S, Van der Loos H, Kenney D . Robot-assisted upper-limb therapy in acute rehabilitation setting following stroke: Department of Veterans Affairs multisite clinical trial. J Rehabil Res Dev. 2011; 48(4):445-58. DOI: 10.1682/jrrd.2010.04.0062. View

4.
Mayr A, Kofler M, Saltuari L . [ARMOR: an electromechanical robot for upper limb training following stroke. A prospective randomised controlled pilot study]. Handchir Mikrochir Plast Chir. 2008; 40(1):66-73. DOI: 10.1055/s-2007-989425. View

5.
Kwakkel G, Wagenaar R, Twisk J, Lankhorst G, Koetsier J . Intensity of leg and arm training after primary middle-cerebral-artery stroke: a randomised trial. Lancet. 1999; 354(9174):191-6. DOI: 10.1016/S0140-6736(98)09477-X. View