Fatigue Resistance of CAD/CAM Complete Crowns with a Simplified Cementation Process

Overview
Journal J Prosthet Dent
Specialty Dentistry
Date 2014 Jan 7
PMID 24388720
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

Statement Of Problem: Various computer-aided design and computer-aided manufacturing (CAD/CAM) materials are available to fabricate complete crowns. The type of material may have an effect on the longevity of these restorations.

Purpose: To evaluate the fatigue resistance, load-to-failure, failure mode, and antagonistic wear of complete molar computer-aided design and computer-aided manufacturing (CAD/CAM) crowns made of resin nanoceramic (RNC), feldspathic glass ceramic (FEL), or lithium disilicate (LD) placed with a simplified cementation process.

Material And Methods: Forty-five molars received a standardized complete crown preparation and were restored with CAD/CAM crowns (1.5-mm thickness, n=15) made of RNC, FEL, and LD. After cementation, the restorations were submitted to cyclic isometric loading: 200 (×5000), 400, 600, 800, 1000, 1200, and 1400 N at a maximum of 30 000 cycles each. Surviving specimens were axially loaded until failure or to a maximum load of 4500 N. The specimens were analyzed as to failure mode: catastrophic, possibly repairable, and repairable. The groups were compared by using the life table survival analysis and the t test (α=.05).

Results: All the specimens survived the fatigue process until the 800-N step. The survival rate of RNC was 80%, LD 93.3%, and FEL 6.6%. The survival of RNC and LD crowns did not differ from each other but exceeded that of FEL. Postfatigue load-to-failure test was 2500 N (FEL), 3122 N (RNC), and 3237 N (LD). No catastrophic failure occurred in the fatigue test, whereas all of the specimens in the load-to-failure test exhibited catastrophic fractures. Crowns made of RNC seemed to generate the least amount of antagonistic wear.

Conclusions: Posterior crowns made of RNC and LD were not statistically different, and both had significantly higher fatigue resistance than FEL. All materials survived beyond the normal range of masticatory forces, and all failures were possibly re-restorable except those in the load-to-failure test. RNC crowns seemed to cause less wear of the antagonist.

Citing Articles

Effect of aging on the marginal fit of milled and printed zirconia crowns: an in-vitro study.

Elsayed M, El-Kouedi A, Shokry T BMC Oral Health. 2025; 25(1):221.

PMID: 39934766 PMC: 11817762. DOI: 10.1186/s12903-025-05542-0.


Evaluation of the Color Stability of Three Resin-Ceramic Materials Using a Spectrophotometer and a Digital Photography Software.

Naffah N, Ounsi H, Ozcan M, Salameh Z Contemp Clin Dent. 2024; 15(1):44-50.

PMID: 38707666 PMC: 11068248. DOI: 10.4103/ccd.ccd_656_18.


Influence of Cementation Mode and Ferrule Design on the Fatigue Resistance of Monolithic Zirconia Endocrowns.

Stoilov M, Boehmer T, Stoilov L, Stark H, Marder M, Enkling N J Clin Med. 2024; 13(4).

PMID: 38398475 PMC: 10889707. DOI: 10.3390/jcm13041165.


Fatigue behavior of three thin CAD/CAM all-ceramic crown materials.

Bataineh K, Al Janaideh M Int Biomech. 2024; 10(1):1-8.

PMID: 38205926 PMC: 10786422. DOI: 10.1080/23335432.2024.2303121.


Resin cement selection for different types of fixed partial coverage restorations: A narrative systematic review.

Ghodsi S, Shekarian M, Aghamohseni M, Rasaeipour S, Arzani S Clin Exp Dent Res. 2023; 9(6):1096-1111.

PMID: 37427500 PMC: 10728549. DOI: 10.1002/cre2.761.