Abstract

Spirometry is regarded as the only effective method for detecting pulmonary function test (PFT) indices. In this study, a novel impedance pulmonary function measurement system (IPFS) is developed for directly assessing PFT indices. IPFS can obtain high resolution values and remove motion artifacts through real-time base impedance feedback. Feedback enables the detection of PFT indices using only both hands for convenience. IPFS showed no differences in the sitting, supine, and standing postures during the measurements, indicating that patient posture has no effect on IPFS. Mean distance analysis showed good agreement between the volume and flow signal of IPFS (p < 0.05). PFT indices were detected in subjects to differentiate a chronic obstructive pulmonary disease (COPD) patient group from a normal group. The forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), FEV1/FVC, and peak expiratory flow (PEF) in the COPD group were lower than those in the normal group by IPFS (p < 0.05). IPFS is therefore suitable for evaluating pulmonary function in normal and COPD patients. Moreover, IPFS could be useful for periodic monitoring of existing patients diagnosed with obstructive lung disease.

Citing Articles

Electrical Bioimpedance Spectroscopy on Acute Unilateral Stroke Patients: Initial Observations regarding Differences between Sides.

Seoane F, Atefi S, Tomner J, Kostulas K, Lindecrantz K Biomed Res Int. 2015; 2015:613247.

PMID: 26557680 PMC: 4628745. DOI: 10.1155/2015/613247.


Feasibility study of a sensor-based autonomous load control exercise training system for COPD patients.

Song B, Becker M, Gietzelt M, Haux R, Kohlmann M, Schulze M J Med Syst. 2014; 39(1):150.

PMID: 25486890 DOI: 10.1007/s10916-014-0150-x.

References
1.
Siafakas N, Vermeire P, Pride N, Paoletti P, Gibson J, Howard P . Optimal assessment and management of chronic obstructive pulmonary disease (COPD). The European Respiratory Society Task Force. Eur Respir J. 1995; 8(8):1398-420. DOI: 10.1183/09031936.95.08081398. View

2.
Carry P, Baconnier P, Eberhard A, Cotte P, Benchetrit G . Evaluation of respiratory inductive plethysmography: accuracy for analysis of respiratory waveforms. Chest. 1997; 111(4):910-5. DOI: 10.1378/chest.111.4.910. View

3.
Allison R, Holmes E, NYBOER J . VOLUMETRIC DYNAMICS OF RESPIRATION AS MEASURED BY ELECTRICAL IMPEDANCE PLETHYSMOGRAPHY. J Appl Physiol. 1964; 19:166-73. DOI: 10.1152/jappl.1964.19.1.166. View

4.
HAMILTON L, Beard J, Carmean R, KORY R . An electrical impedance ventilometer to quantitate tidal volume and ventilation. Med Res Eng. 1967; 6(1):11-6. View

5.