» Articles » PMID: 24157244

3D-Finite Element Analysis of Molars Restored with Endocrowns and Posts During Masticatory Simulation

Overview
Journal Dent Mater
Specialty Dentistry
Date 2013 Oct 26
PMID 24157244
Citations 29
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The objective was to compare equivalent stresses in molars restored with endocrowns as well as posts and cores during masticatory simulation using finite element analysis.

Methods: Four three-dimensional models of first mandibular molars were created: A - intact tooth; B - tooth restored by ceramic endocrown; C - tooth with FRC posts, composite core and ceramic crown; D - tooth with cast post and ceramic crown. The study was performed using finite element analysis, with contact elements. The computer simulations of mastication were conducted. The equivalent stresses of modified von Mises failure criterion (mvM) in models were calculated, Tsai-Wu index for FRC post was determinate. Maximal values of the stresses in the ceramic, cement and dentin were compared between models and to strength of the materials. Contact stresses in the cement-tissue adhesive interface around restorations were considered as well.

Results: During masticatory simulation, the lowest mvM stresses in dentin arisen in molar restored with endocrown (Model B). Maximal mvM stress values in structures of restored molar were 23% lower than in the intact tooth. The mvM stresses in the endocrown did not exceed the tensile strength of ceramic. In the molar with an FRC posts (Model C), equivalent stress values in dentin increased by 42% versus Model B. In ceramic crown of Model C the stresses were 31% higher and in the resin luting cement were 61% higher than in the tooth with endocrown. Tensile contact stresses in the adhesive cement-dentin interface around FRC posts achieved 4 times higher values than under endocrown and shear stresses increased twice. The contact stress values around the appliances were several time smaller than cement-dentin bond strength.

Significance: Teeth restored by endocrowns are potentially more resistant to failure than those with FRC posts. Under physiological loads, ceramic endocrowns ideally cemented in molars should not be demaged or debonded.

Citing Articles

Mode of failure and finite element analysis of custom-made PEEK post-core (milled and pressed).

Abdelmohsen N, Wahsh M, Zohdy M, Abdelfattah G, Alhotan A, Refaie A Odontology. 2025; .

PMID: 40087258 DOI: 10.1007/s10266-025-01084-7.


Fracture resistance, failure mode and restorability of CAD CAM Zirconia endocrowns with different pulpal extension depths bonded to maxillary molars: an in-vitro study.

Gaafar S, El Ballouli D, Rayyan M, Sayed M, Basta D, Fouad M BMC Oral Health. 2025; 25(1):176.

PMID: 39893449 PMC: 11786583. DOI: 10.1186/s12903-025-05466-9.


Effect of different restorative design and materials on stress distribution in cracked teeth: a finite element analysis study.

Liu T, Huang Y, Li Y, Meng J, Liu Y, Wei Y BMC Oral Health. 2025; 25(1):31.

PMID: 39773215 PMC: 11706048. DOI: 10.1186/s12903-024-05122-8.


Clinical Effect of Feldspar Glass Ceramics and Lithium Disilicate Reinforced Glass Ceramics.

Liu C, Yang S, Chu X Contrast Media Mol Imaging. 2024; 2022:9691594.

PMID: 39281828 PMC: 11401703. DOI: 10.1155/2022/9691594.


Comparative evaluation of incorporation of ferrule in premolars endocrown designs to check any alterations in their fracture resistance: A pilot study.

Pal P, Mazumdar D, Bera S, Kar S, Sahay D, Chowdhuri K J Conserv Dent Endod. 2024; 27(7):730-736.

PMID: 39262600 PMC: 11385903. DOI: 10.4103/JCDE.JCDE_277_24.