Bioharness(™) Multivariable Monitoring Device: Part. I: Validity

Overview
Specialty Orthopedics
Date 2013 Oct 24
PMID 24149346
Citations 41
Authors
Affiliations
Soon will be listed here.
Abstract

The Bioharness(™) monitoring system may provide physiological information on human performance but there is limited information on its validity. The objective of this study was to assess the validity of all 5 Bioharness(™) variables using a laboratory based treadmill protocol. 22 healthy males participated. Heart rate (HR), Breathing Frequency (BF) and Accelerometry (ACC) precision were assessed during a discontinuous incremental (0-12 km·h(-1)) treadmill protocol. Infra-red skin temperature (ST) was assessed during a 45 min(-1) sub-maximal cycle ergometer test, completed twice, with environmental temperature controlled at 20 ± 0.1 °C and 30 ± 0.1 °C. Posture (P) was assessed using a tilt table moved through 160°. Adopted precision of measurement devices were; HR: Polar T31 (Polar Electro), BF: Spirometer (Cortex Metalyser), ACC: Oxygen expenditure (Cortex Metalyser), ST: Skin thermistors (Grant Instruments), P:Goniometer (Leighton Flexometer). Strong relationships (r = .89 to .99, p < 0.01) were reported for HR, BF, ACC and P. Limits of agreement identified differences in HR (-3.05 ± 32.20 b·min(-1)), BF (-3.46 ± 43.70 br·min(-1)) and P (0.20 ± 2.62°). ST established a moderate relationships (-0.61 ± 1.98 °C; r = 0.76, p < 0.01). Higher velocities on the treadmill decreased the precision of measurement, especially HR and BF. Global results suggest that the BioharressTM is a valid multivariable monitoring device within the laboratory environment. Key pointsDifferent levels of precision exist for each variable in the Bioharness(™) (Version 1) multi-variable monitoring deviceAccelerometry and posture variables presented the most precise dataData from the heart rate and breathing frequency variable decrease in precision at velocities ≥ 10 km·h(-1)Clear understanding of the limitations of new applied monitoring technology is required before it is used by the exercise scientist.

Citing Articles

A Novel Unsupervised Machine Learning Approach to Assess Postural Dynamics in Euthymic Bipolar Disorder.

Halabi R, Gonzalez-Torres C, MacLean S, Husain M, Pratap A, Alda M IEEE J Biomed Health Inform. 2024; 28(8):4903-4911.

PMID: 38691437 PMC: 11303098. DOI: 10.1109/JBHI.2024.3394754.


PreEpiSeizures: description and outcomes of physiological data acquisition using wearable devices during video-EEG monitoring in people with epilepsy.

Abreu M, Carmo A, Peralta A, Sa F, da Silva H, Bentes C Front Physiol. 2023; 14:1248899.

PMID: 37881691 PMC: 10597694. DOI: 10.3389/fphys.2023.1248899.


A History of Suicide Attempt Is Associated with Increased Sympathetic Activation in Bipolar Disorder.

Ortiz A, Park Y, MacLean S, Husain M, Sanches M, Ravindran A Can J Psychiatry. 2023; 69(2):126-137.

PMID: 37583363 PMC: 10789230. DOI: 10.1177/07067437231194334.


G Tolerance Prediction Model Using Mobile Device-Measured Cardiac Force Index for Military Aircrew: Observational Study.

Kuo M, Lin Y, Huang W, Chiang K, Tu M, Chu C JMIR Mhealth Uhealth. 2023; 11:e48812.

PMID: 37494088 PMC: 10413232. DOI: 10.2196/48812.


Preliminary Assessment of a Flexible Multi-Sensor Wearable System Based on Fiber Bragg Gratings for Respiratory Monitoring of Hemiplegic Patients.

Zaltieri M, Massaroni C, Di Tocco J, Bravi M, Morrone M, Sterzi S Int J Environ Res Public Health. 2022; 19(20).

PMID: 36294108 PMC: 9603331. DOI: 10.3390/ijerph192013525.


References
1.
Hansson G, Asterland P, Holmer N, Skerfving S . Validity and reliability of triaxial accelerometers for inclinometry in posture analysis. Med Biol Eng Comput. 2001; 39(4):405-13. DOI: 10.1007/BF02345361. View

2.
Finni T, Hu M, Kettunen P, Vilavuo T, Cheng S . Measurement of EMG activity with textile electrodes embedded into clothing. Physiol Meas. 2007; 28(11):1405-19. DOI: 10.1088/0967-3334/28/11/007. View

3.
Matsukawa T, Ozaki M, Nishiyama T, Imamura M, Kumazawa T . Comparison of infrared thermometer with thermocouple for monitoring skin temperature. Crit Care Med. 2000; 28(2):532-6. DOI: 10.1097/00003246-200002000-00041. View

4.
Welk G . Principles of design and analyses for the calibration of accelerometry-based activity monitors. Med Sci Sports Exerc. 2005; 37(11 Suppl):S501-11. DOI: 10.1249/01.mss.0000185660.38335.de. View

5.
Bernmark E, Wiktorin C . A triaxial accelerometer for measuring arm movements. Appl Ergon. 2003; 33(6):541-7. DOI: 10.1016/s0003-6870(02)00072-8. View