» Articles » PMID: 24148779

Coronary CT Angiography Versus Intravascular Ultrasound for Estimation of Coronary Stenosis and Atherosclerotic Plaque Burden: a Meta-analysis

Overview
Publisher Elsevier
Date 2013 Oct 24
PMID 24148779
Citations 55
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Numerous studies have compared coronary CT angiography (CTA) with quantitative coronary angiography. However, the ability of coronary CTA to identify atherosclerosis and to accurately measure plaque and coronary area and volume measurements as compared with intravascular ultrasound (IVUS) has not been fully defined.

Objective: We sought to assess the ability of coronary CTA to quantify coronary and plaque measurements commonly performed with IVUS.

Methods: We searched multiple databases for diagnostic studies that directly compared coronary CTA and IVUS for coronary plaque detection, vessel luminal area, percentage of area stenosis, plaque area, and plaque volume. We used a bivariate mixed-effects binomial regression model to pool test sensitivity and specificity for detection of any coronary plaque.

Results: Forty-two studies that evaluated 1360 patients (75% men; mean age, 59 years) were identified. No significant difference was found between coronary CTA and IVUS measurements of vessel lumen cross-sectional area, plaque area, percentage of area stenosis, or plaque volume within the overall cohort and no difference for the measurement of cross-sectional area (n = 5 studies) and plaque volume (n = 8 studies) among a subgroup that used automated or semiautomated measurement techniques. Sensitivity and specificity of coronary CTA to detect any plaque compared with IVUS were 93% and 92%, respectively, with an area under the receiver-operating curve of 0.97.

Conclusions: Compared with IVUS, coronary CTA appears to be highly accurate for estimation of luminal area, percentage of area stenosis, plaque volume, and plaque area and for detection of plaque. The use of automated vessel and stenosis measurements appears promising in limited studies to date.

Citing Articles

Prediction of plaque progression using different machine learning models of pericoronary adipose tissue radiomics based on coronary computed tomography angiography.

Pan J, Huang Q, Zhu J, Huang W, Wu Q, Fu T Eur J Radiol Open. 2025; 14:100638.

PMID: 40034660 PMC: 11872547. DOI: 10.1016/j.ejro.2025.100638.


Computed Tomography Angiography in the Catheterization Laboratory: A Guide Towards Optimizing Coronary Interventions.

Beneki E, Dimitriadis K, Pyrpyris N, Antonopoulos A, Aznaouridis K, Antiochos P J Cardiovasc Dev Dis. 2025; 12(1).

PMID: 39852306 PMC: 11766008. DOI: 10.3390/jcdd12010028.


Diagnostic Performance of AI-enabled Plaque Quantification from Coronary CT Angiography Compared with Intravascular Ultrasound.

Ihdayhid A, Tzimas G, Peterson K, Ng N, Mirza S, Maehara A Radiol Cardiothorac Imaging. 2024; 6(6):e230312.

PMID: 39540820 PMC: 11683154. DOI: 10.1148/ryct.230312.


Computed Tomography Evaluation of Coronary Atherosclerosis: The Road Travelled, and What Lies Ahead.

Ayoub C, Scalia I, Anavekar N, Arsanjani R, Jokerst C, Chow B Diagnostics (Basel). 2024; 14(18).

PMID: 39335775 PMC: 11431535. DOI: 10.3390/diagnostics14182096.


Coronary Atherosclerotic Plaque Burden Assessment by Computed Tomography and Its Clinical Implications.

Vatsa N, Faaborg-Andersen C, Dong T, Blaha M, Shaw L, Quintana R Circ Cardiovasc Imaging. 2024; 17(8):e016443.

PMID: 39163370 PMC: 11566462. DOI: 10.1161/CIRCIMAGING.123.016443.