» Articles » PMID: 24142562

The Effect of Precordial Lead Displacement on ECG Morphology

Overview
Publisher Springer
Date 2013 Oct 22
PMID 24142562
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Inaccurate electrode placement and differences in inter-individual human anatomies can lead to misinterpretation of ECG examination. The aim of the study was to investigate the effect of precordial electrodes displacement on morphology of the ECG signal in a group of 60 patients with diagnosed cardiac disease. Shapes of ECG signals recorded from precordial leads were compared with signals interpolated at the points located at a distance up to 5 cm from lead location. Shape differences of the QRS and ST-T-U complexes were quantified using the distribution function method, correlation coefficient, root-mean-square error (RMSE), and normalized RMSE. The relative variability (RV) index was calculated to quantify inter-individual variability. ECG morphology changes were prominent in all shape parameters beyond 2 cm distance to precordial leads. Lead V2 was the most sensitive to displacement errors, followed by leads V3, V1, and V4, for which the direction of electrodes displacement plays a key role. No visible changes in ECG morphology were observed in leads V5 and V6, only scaling effect of signal amplitude. The RV ranged from 0.639 to 0.989. Distortions in ECG tracings increase with the distance from precordial lead, which are specific to chosen electrode, direction of displacement, and for ECG segment selected for calculations.

Citing Articles

Empagliflozin's role in reducing ventricular repolarization heterogeneity: insights into cardiovascular mortality decline from the EMPATHY-HEART trial.

Lauretti C, Antonio G, Fernandes A, Stocco F, Girardi A, Verrier R Cardiovasc Diabetol. 2024; 23(1):221.

PMID: 38926835 PMC: 11210164. DOI: 10.1186/s12933-024-02311-1.


Sensitivity of Electrocardiogram on Electrode-Pair Locations for Wearable Devices: Computational Analysis of Amplitude and Waveform Distortion.

Sanjo K, Hebiguchi K, Tang C, Rashed E, Kodera S, Togo H Biosensors (Basel). 2024; 14(3).

PMID: 38534260 PMC: 10968092. DOI: 10.3390/bios14030153.


Limited Relationship Between Echocardiographic Measures and Electrocardiographic Markers of Left Ventricular Size in Healthy Children.

Alexander M, Gongwer R, Trachtenberg F, Minich L, Triedman J, Kaltman J Pediatr Cardiol. 2024; 45(5):1055-1063.

PMID: 38520508 DOI: 10.1007/s00246-024-03448-2.


Prediction of hyperkalemia in ESRD patients by identification of multiple leads and multiple features on ECG.

Xu D, Zhou B, Zhang J, Li C, Guan C, Liu Y Ren Fail. 2023; 45(1):2212800.

PMID: 37199267 PMC: 10197982. DOI: 10.1080/0886022X.2023.2212800.


Motion Artifact Reduction in Electrocardiogram Signals Through a Redundant Denoising Independent Component Analysis Method for Wearable Health Care Monitoring Systems: Algorithm Development and Validation.

Castano Usuga F, Gissel C, Hernandez A JMIR Med Inform. 2022; 10(11):e40826.

PMID: 36274196 PMC: 9736764. DOI: 10.2196/40826.


References
1.
Carley S, Jenkins M, Mackway Jones K . Body surface mapping versus the standard 12 lead ECG in the detection of myocardial infarction amongst emergency department patients: a Bayesian approach. Resuscitation. 2005; 64(3):309-14. DOI: 10.1016/j.resuscitation.2004.10.002. View

2.
Kligfield P, Gettes L, Bailey J, Childers R, Deal B, Hancock E . Recommendations for the standardization and interpretation of the electrocardiogram. Part I: The electrocardiogram and its technology. A scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council.... Heart Rhythm. 2007; 4(3):394-412. DOI: 10.1016/j.hrthm.2007.01.027. View

3.
van Oosterom A, Hoekema R, Uijen G . Geometrical factors affecting the interindividual variability of the ECG and the VCG. J Electrocardiol. 2001; 33 Suppl:219-27. DOI: 10.1054/jelc.2000.20356. View

4.
Finlay D, Nugent C, Nelwan S, Bond R, Donnelly M, Guldenring D . Effects of electrode placement errors in the EASI-derived 12-lead electrocardiogram. J Electrocardiol. 2010; 43(6):606-11. DOI: 10.1016/j.jelectrocard.2010.07.004. View

5.
Schijvenaars R, Kors J, van Herpen G, van Bemmel J . Use of the standard 12-lead ECG to simulate electrode displacements. J Electrocardiol. 1996; 29 Suppl:5-9. DOI: 10.1016/s0022-0736(96)80002-1. View