The Effects of Saliva Collection, Handling and Storage on Salivary Testosterone Measurement

Overview
Journal Steroids
Publisher Elsevier
Specialty Biochemistry
Date 2013 Sep 21
PMID 24051109
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Several endocrine parameters commonly measured in plasma, such as steroid hormones, can be measured in the oral fluid. However, there are several technical aspects of saliva sampling and processing that can potentially bias the validity of salivary testosterone measurement. The aim of this study was to evaluate the effects caused by repeated sampling; 5 min centrifugation (at 2000, 6000 or 10,000g); the stimulation of saliva flow by a cotton swab soaked in 2% citric acid touching the tongue; different storage times and conditions as well as the impact of blood contamination on salivary testosterone concentration measured using a commercially available ELISA kit. Fresh, unprocessed, unstimulated saliva samples served as a control. Salivary testosterone concentrations were influenced neither by repeated sampling nor by stimulation of salivary flow. Testosterone levels determined in samples stored in various laboratory conditions for time periods up to 1 month did not differ in comparison with controls. For both genders, salivary testosterone levels were substantially reduced after centrifugation (men F=29.1; women F=56.17, p<0.0001). Blood contamination decreased salivary testosterone levels in a dose-dependent manner (men F=6.54, p<0.01, F=5.01, p<0.05). Salivary testosterone can be considered A robust and stable marker. However, saliva processing and blood leakage can introduce bias into measurements of salivary testosterone using ELISA. Our observations should be considered in studies focusing on salivary testosterone.

Citing Articles

Welfare Assessment in Pigs Using the Salivary Proteome.

Prims S, Van Ginneken C, Van Ostade X, Casteleyn C Animals (Basel). 2024; 14(11).

PMID: 38891749 PMC: 11171187. DOI: 10.3390/ani14111703.


Salivary Sex Steroid Levels in Infants and the Relation with Infantile Colic.

Kalayci F, Gursoy Doruk O, Erbas I, Ince O, Tan M, Aydin A J Clin Res Pediatr Endocrinol. 2024; 16(2):185-191.

PMID: 38347685 PMC: 11590717. DOI: 10.4274/jcrpe.galenos.2024.2023-11-2.


Extensive comparison of salivary collection, transportation, preparation, and storage methods: a systematic review.

Mortazavi H, Yousefi-Koma A, Yousefi-Koma H BMC Oral Health. 2024; 24(1):168.

PMID: 38308289 PMC: 10837873. DOI: 10.1186/s12903-024-03902-w.


Enzymatic Methods for Salivary Biomarkers Detection: Overview and Current Challenges.

Ornelas-Gonzalez A, Ortiz-Martinez M, Gonzalez-Gonzalez M, Rito-Palomares M Molecules. 2021; 26(22).

PMID: 34834116 PMC: 8624596. DOI: 10.3390/molecules26227026.


Potential of Salivary Biomarkers in Autism Research: A Systematic Review.

Jansakova K, Kyselicova K, Ostatnikova D, Repiska G Int J Mol Sci. 2021; 22(19).

PMID: 34639213 PMC: 8509590. DOI: 10.3390/ijms221910873.