» Articles » PMID: 2399307

Storage Phosphor Versus Screen-film Radiography: Effect of Varying Exposure Parameters and Unsharp Mask Filtering on the Detectability of Cortical Bone Defects

Overview
Journal Radiology
Specialty Radiology
Date 1990 Oct 1
PMID 2399307
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Diagnostic performance with storage phosphor radiography is influenced by exposure parameters and digital filtering algorithms. The authors compared the detectability of cortical lesions in excised human femoral shafts on state-of-the-art screen-film radiographs and storage phosphor digital radiographs. For the digital system, the effect of varying exposure parameters (photon flux and tube voltage) and unsharp mask filtering (kernel size and enhancement factor) was tested. Analysis of receiver operating characteristics was performed for 10,560 observations made by eight radiologists. Under identical exposure conditions, storage phosphor imaging yielded no significant advantages over conventional screen-film radiography. Although large variations in exposure dose are possible with storage phosphors, the potential for dose reduction was limited even by means of an increase in tube voltage. The performance with unsharp masked images declined with decreasing kernel size and pronounced enhancement.

Citing Articles

Computed radiography excretory urography: can the system sensitivity value be used as an image quality indicator?.

Andoh K, Odagiri K, Matsumoto T, Yamashita K, Ogino I, Otsuka T J Digit Imaging. 1997; 10(3):132-6.

PMID: 9268909 PMC: 3452950. DOI: 10.1007/BF03168601.


Support line and tube visibility in chest examinations using computed radiography.

Huda W, Belden C, Webb L, Palmer C J Digit Imaging. 1997; 10(3):126-31.

PMID: 9268908 PMC: 3452951. DOI: 10.1007/BF03168600.


Comparison of stimulable phosphor technology and conventional screen-film technology in pediatric scoliosis.

Stringer D, Cairns R, Poskitt K, Bray H, Milner R, Kennedy B Pediatr Radiol. 1994; 24(1):1-5.

PMID: 8008484 DOI: 10.1007/BF02017647.


A comparison of hard and soft copies processed with linear conversion and nonlinear conversion of skeletal fractures--a preliminary study.

Kaji T, Katayama M, Kosuda S, Kusano S J Digit Imaging. 1995; 8(1 Suppl 1):45-50.

PMID: 7734540 DOI: 10.1007/BF03168067.


Visualization of multimodal image information in medicine.

Englmeier K, Fink U, Hilbertz T Proc Annu Symp Comput Appl Med Care. 1992; :25-9.

PMID: 1482876 PMC: 2248007.