» Articles » PMID: 23974909

Determination of Cardiac Output with Dynamic Contrast-enhanced Computed Tomography

Overview
Publisher Springer
Specialty Radiology
Date 2013 Aug 27
PMID 23974909
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Cardiac output (CO) is an important diagnostic and prognostic factor in the haemodynamic evaluation of patients. The gold standard for CO measurement, thermodilution, requires an invasive right-heart catheterisation (RHC). In this pilot study we aimed to determine the accuracy of non-invasive CO determination from dynamic contrast-enhanced computed tomography (CT) compared to thermodilution. Patients who underwent diagnostic or follow-up RHC due to suspected or known pulmonary vascular disease at our department and required a thoracic CT between June 2011 and August 2012 were included. CO was determined from CT attenuation-time curves in the pulmonary artery and the ascending aorta using a dynamic contrast-enhanced CT sequence. CO determined in N = 18 patients by dynamic CT in the pulmonary artery was in very good agreement with thermodilution data (r = 0.84). Bland-Altman analysis showed a systematic overestimation of 0.7 ± 0.6 l/min compared to thermodilution. Data from the ascending aorta also showed a good correlation, but with a larger scattering of the values. The average effective dose for the dynamic investigation was 1.2 ± 0.7 mSv. CO determined with dynamic contrast-enhanced CT in the main pulmonary artery reliably predicts the values obtained by thermodilution during RHC. This non-invasive technique might provide an alternative for repeated invasive right-heart catheter investigations in the follow-up of pulmonary arterial hypertension patients.

Citing Articles

Pulmonary CT perfusion robustly measures cardiac output in the context of multilevel pulmonary occlusion: a porcine study.

Silva D, Muders T, Wodack K, Putensen C, Leonhardt S, Siepmann R Eur Radiol Exp. 2024; 8(1):51.

PMID: 38517595 PMC: 10959917. DOI: 10.1186/s41747-024-00431-7.


Effect of Cardiac Phase on Cardiac Output Index Derived from Dynamic CT Myocardial Perfusion Imaging.

Dempsey S, Lee T, Samani A, So A Tomography. 2022; 8(2):1129-1140.

PMID: 35448726 PMC: 9024735. DOI: 10.3390/tomography8020092.


A Novel Statistical Optimization Algorithm for Estimating Perfusion Curves in Susceptibility Contrast-Enhanced MRI.

Hu Z, Li F, Shui J, Tang Y, Lin Q Front Neurosci. 2021; 15:713893.

PMID: 34512247 PMC: 8427443. DOI: 10.3389/fnins.2021.713893.


Effects of Sedation by Intramuscular Administration of Medetomidine on Canine Abdominal Vascular System and Hepatic Parenchyma Imaging Using Enhancement Dynamic Computed Tomography.

Kutara K, Kanda T, Maeta N, Mochizuki Y, Itoh Y, Ono F Vet Sci. 2020; 7(3).

PMID: 32668593 PMC: 7558173. DOI: 10.3390/vetsci7030091.


Higher enhanced computed tomography attenuation value of the aorta is a predictor of massive transfusion in blunt trauma patients.

Yumoto T, Ihoriya H, Tanabe R, Naito H, Nakao A Clin Exp Emerg Med. 2020; 6(4):330-339.

PMID: 31910504 PMC: 6952635. DOI: 10.15441/ceem.18.090.


References
1.
. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007; 37(2-4):1-332. DOI: 10.1016/j.icrp.2007.10.003. View

2.
Raman S, Tran T, Simonetti O, Sun B . Dynamic computed tomography to determine cardiac output in patients with left ventricular assist devices. J Thorac Cardiovasc Surg. 2009; 137(5):1213-7. DOI: 10.1016/j.jtcvs.2008.10.043. View

3.
Meyer S, Todd D, Wright I, Gortner L, Reynolds G . Review article: Non-invasive assessment of cardiac output with portable continuous-wave Doppler ultrasound. Emerg Med Australas. 2008; 20(3):201-8. DOI: 10.1111/j.1742-6723.2008.01078.x. View

4.
Du Bois D, Du Bois E . A formula to estimate the approximate surface area if height and weight be known. 1916. Nutrition. 1989; 5(5):303-11; discussion 312-3. View

5.
Mahnken A, Klotz E, Hennemuth A, Jung B, Koos R, Wildberger J . Measurement of cardiac output from a test-bolus injection in multislice computed tomography. Eur Radiol. 2003; 13(11):2498-504. DOI: 10.1007/s00330-003-2054-x. View