» Articles » PMID: 23957594

Reduced Lung Dose and Improved Inspiration Level Reproducibility in Visually Guided DIBH Compared to Audio Coached EIG Radiotherapy for Breast Cancer Patients

Overview
Journal Acta Oncol
Specialty Oncology
Date 2013 Aug 21
PMID 23957594
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Patients with left-sided breast cancer with lymph node involvement have routinely been treated with enhanced inspiration gating (EIG) for a decade at our institution. In a transition from EIG to deep inspiration breath hold (DIBH) we compared the two techniques with focus on target coverage, dose to organs at risk and reproducibility of the inspiration level (IL).

Material And Methods: Twenty-four patients were computed tomography (CT) scanned with EIG and DIBH. For DIBH we used visual feedback and for EIG audio coaching, both during scan and treatment. Treatment plans for 50 Gy over 25 fractions were calculated. Seventeen of the patients were included in the analysis of reproducibility. They were audio coached for one minute before beam-on in DIBH at nine treatment sessions. These respiration curves were analysed with average maximum IL and standard deviation (SD) for the EIG part of the respiratory signal, and mean IL and SD for the DIBH. Comparison of dosimetric and respiration parameters were performed with the Wilcoxon signed rank-sum test.

Results: In DIBH, the ipsilateral lung volume increased further compared to EIG (p < 0.0004, mean increase 11%). This lead to a 9% mean reduction (p = 0.002) of the ipsilateral lung volume receiving 20 Gy (V20 Gy). We found no other significant dosimetric differences between the two methods. The reproducibility of the IL was better with the DIBH method, observed as a significantly smaller SD in most patients (p < 0.04 for 16 of 17 patients).

Conclusion: The DIBH method resulted in a significantly larger lung volume and lower ipsilateral lung V20 Gy compared to EIG. The IL for visually guided DIBH was more reproducible than audio-coached EIG. Based on these findings, the DIBH technique is our new breathing adaptation standard for radiotherapy of patients with left-sided breast cancer with lymph node involvement.

Citing Articles

Prospective Randomized Trial Comparing 2 Devices for Deep Inspiration Breath Hold Management in Breast Radiation Therapy: Results of the BRAVEHeart Trial.

Byrne H, Steiner E, Booth J, Lamoury G, Morgia M, Carroll S Adv Radiat Oncol. 2024; 9(9):101572.

PMID: 39221134 PMC: 11364044. DOI: 10.1016/j.adro.2024.101572.


BRAVEHeart: a randomised trial comparing the accuracy of Breathe Well and RPM for deep inspiration breath hold breast cancer radiotherapy.

Byrne H, Steiner E, Booth J, Lamoury G, Morgia M, Richardson K Trials. 2023; 24(1):132.

PMID: 36814310 PMC: 9945402. DOI: 10.1186/s13063-023-07072-y.


Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran.

Abdollahi S, Yazdi M, Mowlavi A, Ceberg S, Aznar M, Varshoee Tabrizi F Rep Pract Oncol Radiother. 2022; 27(5):881-896.

PMID: 36523810 PMC: 9746649. DOI: 10.5603/RPOR.a2022.0103.


A phase 2 trial of deep-inspiration breath hold in radiotherapy of gastric lymphomas.

Petersen P, Rechner L, Specht L Phys Imaging Radiat Oncol. 2022; 22:137-141.

PMID: 35865617 PMC: 9295184. DOI: 10.1016/j.phro.2022.05.008.


Radiation-Induced Toxicity Risks in Photon Versus Proton Therapy for Synchronous Bilateral Breast Cancer.

Stick L, Jensen M, Bentzen S, Kamby C, Lundgaard A, Maraldo M Int J Part Ther. 2022; 8(4):1-13.

PMID: 35530186 PMC: 9009461. DOI: 10.14338/IJPT-21-00023.1.