» Articles » PMID: 23947902

The CASCADE Trial: Effectiveness of Ceramic Versus PEEK Cages for Anterior Cervical Discectomy with Interbody Fusion; Protocol of a Blinded Randomized Controlled Trial

Overview
Publisher Biomed Central
Specialties Orthopedics
Physiology
Date 2013 Aug 17
PMID 23947902
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Anterior cervical discectomy with interbody fusion cages is considered the standard surgical procedure in patients with cervical disc herniation. However, PEEK or metal cages have some undesirable imaging characteristics, leading to a search for alternative materials not creating artifacts on images; silicon nitride ceramic. Whether patients treated with silicon nitride ceramic cages have similar functional outcome as patients treated with PEEK cages is not known. We present the design of the CASCADE trial on effectiveness of ceramic cages versus PEEK cages in patients with cervical disc herniation and/or osteophytes.

Methods/design: Patients (age 18-75 years) with monoradicular symptoms in one or both arms lasting more than 8 weeks, due to disc herniation and/or osteophytes, are eligible for the trial. The study is designed as a randomized controlled equivalence trial in which patients are blinded to the type of cage for 1 year. The total follow-up period is 2 years. The primary outcome measure is improvement in the Neck and Disability Index (NDI). Secondary outcomes measures include improvement in arm pain and neck pain (VAS), SF-36 and patients' perceived recovery. The final elements of comparison are perioperative statistics including operating time, blood loss, length of hospital stay, and adverse events. Lateral plane films at each follow-up visit and CT scan (at 6 months) will be used to judge fusion and the incidence of subsidence. Based on a power of 90% and assuming 8% loss to follow-up, 100 patients will be randomized into the 2 groups. The first analysis will be conducted when all patients have 1 year of follow-up, and the groups will be followed for 1 additional year to judge stability of outcomes.

Discussion: While the new ceramic cage has received the CE Mark based on standard compliance and animal studies, a randomized comparative study with the golden standard product will provide more conclusive information for clinicians. Implementation of any new device should only be done after completion of randomized controlled effectiveness trials.

Citing Articles

Biological Characteristics of Polyurethane-Based Bone-Replacement Materials.

Egorikhina M, Bokov A, Charykova I, Rubtsova Y, Linkova D, I Kobyakova I Polymers (Basel). 2023; 15(4).

PMID: 36850115 PMC: 9966979. DOI: 10.3390/polym15040831.


Silicon Nitride as a Biomedical Material: An Overview.

Du X, Lee S, Blugan G, Ferguson S Int J Mol Sci. 2022; 23(12).

PMID: 35742996 PMC: 9224221. DOI: 10.3390/ijms23126551.


Radiological and Clinical Outcomes after Anterior Cervical Discectomy and Fusion (ACDF) with an Innovative 3D Printed Cellular Titanium Cage Filled with Vertebral Bone Marrow.

Mayer F, Heider F, Haasters F, Mehren C Biomed Res Int. 2022; 2022:6339910.

PMID: 35528156 PMC: 9071886. DOI: 10.1155/2022/6339910.


Porous silicon nitride spacers versus PEEK cages for anterior cervical discectomy and fusion: clinical and radiological results of a single-blinded randomized controlled trial.

Arts M, Wolfs J, Corbin T Eur Spine J. 2017; 26(9):2372-2379.

PMID: 28382392 DOI: 10.1007/s00586-017-5079-6.


Advances in Spinal Interbody Cages.

Jain S, Eltorai A, Ruttiman R, Daniels A Orthop Surg. 2016; 8(3):278-84.

PMID: 27627709 PMC: 6584167. DOI: 10.1111/os.12264.


References
1.
Vos C, Verhagen A, Koes B . Reliability and responsiveness of the Dutch version of the Neck Disability Index in patients with acute neck pain in general practice. Eur Spine J. 2006; 15(11):1729-36. DOI: 10.1007/s00586-006-0119-7. View

2.
Rudisch A, Kremser C, Peer S, Kathrein A, Judmaier W, Daniaux H . Metallic artifacts in magnetic resonance imaging of patients with spinal fusion. A comparison of implant materials and imaging sequences. Spine (Phila Pa 1976). 1998; 23(6):692-9. DOI: 10.1097/00007632-199803150-00009. View

3.
Dokmak A . Anterior cervical discectomy (ACD) versus anterior cervical fusion (ACF), clinical and radiological outcome study. Acta Neurochir (Wien). 1999; 141(10):1089-92. DOI: 10.1007/s007010050487. View

4.
Bombardier C . Outcome assessments in the evaluation of treatment of spinal disorders: summary and general recommendations. Spine (Phila Pa 1976). 2000; 25(24):3100-3. DOI: 10.1097/00007632-200012150-00003. View

5.
Cho D, Lee W, Liu J, Sheu P . Preliminary experience using a polyetheretherketone (PEEK) cage in the treatment of cervical disc disease. Neurosurgery. 2002; 51(6):1343-49; discussion 1349-50. View