Concurrent Validation of Xsens MVN Measurement of Lower Limb Joint Angular Kinematics

Overview
Journal Physiol Meas
Date 2013 Jul 30
PMID 23893094
Citations 100
Authors
Affiliations
Soon will be listed here.
Abstract

This study aims to validate a commercially available inertial sensor based motion capture system, Xsens MVN BIOMECH using its native protocols, against a camera-based motion capture system for the measurement of joint angular kinematics. Performance was evaluated by comparing waveform similarity using range of motion, mean error and a new formulation of the coefficient of multiple correlation (CMC). Three dimensional joint angles of the lower limbs were determined for ten healthy subjects while they performed three daily activities: level walking, stair ascent, and stair descent. Under all three walking conditions, the Xsens system most accurately determined the flexion/extension joint angle (CMC > 0.96) for all joints. The joint angle measurements associated with the other two joint axes had lower correlation including complex CMC values. The poor correlation in the other two joint axes is most likely due to differences in the anatomical frame definition of limb segments used by the Xsens and Optotrak systems. Implementation of a protocol to align these two systems is necessary when comparing joint angle waveforms measured by the Xsens and other motion capture systems.

Citing Articles

Optimal control simulations tracking wearable sensor signals provide comparable running gait kinematics to marker-based motion capture.

McConnochie G, Fox A, Bellenger C, Thewlis D PeerJ. 2025; 13:e19035.

PMID: 40061227 PMC: 11890300. DOI: 10.7717/peerj.19035.


Comparing sparse inertial sensor setups for sagittal-plane walking and running reconstructions.

Dorschky E, Nitschke M, Mayer M, Weygers I, Gassner H, Seel T Front Bioeng Biotechnol. 2025; 13:1507162.

PMID: 40046809 PMC: 11879983. DOI: 10.3389/fbioe.2025.1507162.


Validity and Reliability of Gait Speed and Knee Flexion Estimated by a Novel Vision-Based Smartphone Application.

Leung K, Li Z, Huang C, Huang X, Fu S Sensors (Basel). 2024; 24(23).

PMID: 39686162 PMC: 11644766. DOI: 10.3390/s24237625.


Gait compensations, pain, and functional performance during the six minute walk test in individuals with unilateral hip osteoarthritis.

Davis-Wilson H, Hoffman R, Cheuy V, Christensen J, Forster J, Judd D Clin Biomech (Bristol). 2024; 120:106366.

PMID: 39490051 PMC: 11789618. DOI: 10.1016/j.clinbiomech.2024.106366.


Validation of inertial measurement units based on waveform similarity assessment against a photogrammetry system for gait kinematic analysis.

Blanco-Coloma L, Garcia-Gonzalez L, Sinovas-Alonso I, Torio-Alvarez S, Martos-Hernandez P, Gonzalez-Exposito S Front Bioeng Biotechnol. 2024; 12:1449698.

PMID: 39193230 PMC: 11348432. DOI: 10.3389/fbioe.2024.1449698.