Laboratory Intercomparison of the Cytokinesis-block Micronucleus Assay

Overview
Journal Radiat Res
Specialties Genetics
Radiology
Date 2013 Jul 19
PMID 23862731
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

The focus of the study is an intercomparison of laboratories' dose-assessment performances using the cytokinesis-block micronucleus (CBMN) assay as a diagnostic triage tool for individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25-5 Gy) as well as blind samples (0.1-6.4 Gy) were sent to the participants. The CBMN assay was performed according to protocols individually established and varying among participating laboratories. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) was calculated and radiation doses were merged into four triage categories reflecting clinical aspects to calculate accuracy, sensitivity and specificity. The earliest report time was 4 days after sample arrival. The CBMN dose estimates were reported with high accuracy (MAD values of 0.20-0.50 Gy at doses below 6.4 Gy for both manual and automated scoring procedures), but showed a limitation of the assay at the dose point of 6.4 Gy, which resulted in a clear dose underestimation in all cases. The MAD values (without 6.4 Gy) differed significantly (P = 0.03) between manual (0.25 Gy, SEM = 0.06, n = 4) or automated scoring procedures (0.37 Gy, SEM = 0.08, n = 5), but lowest MAD were equal (0.2 Gy) for both scoring procedures. Likewise, both scoring procedures led to the same allocation of dose estimates to triage categories of clinical significance (about 83% accuracy and up to 100% specificity).

Citing Articles

Potentials of cytokinesis blocked micronucleus assay in radiation triage and biological dosimetry.

Tamizh Selvan G, Venkatachalam P J Genet Eng Biotechnol. 2024; 22(4):100409.

PMID: 39674629 PMC: 11381789. DOI: 10.1016/j.jgeb.2024.100409.


Development of high-throughput systems for biodosimetry.

Wilkins R, Beaton-Green L Radiat Prot Dosimetry. 2023; 199(14):1477-1484.

PMID: 37721060 PMC: 10720693. DOI: 10.1093/rpd/ncad060.


Improving radiation dosimetry with an automated micronucleus scoring system: correction of automated scoring errors.

Lee Y, Jin Y, Seong K, Wilkins R, Jang S Radiat Environ Biophys. 2023; 62(3):349-356.

PMID: 37195317 PMC: 10356889. DOI: 10.1007/s00411-023-01030-7.


Cytogenetic biological dosimetry assays: recent developments and updates.

Gnanasekaran T Radiat Oncol J. 2021; 39(3):159-166.

PMID: 34610654 PMC: 8497872. DOI: 10.3857/roj.2021.00339.


The use of a centrifuge-free RABiT-II system for high-throughput micronucleus analysis.

Repin M, Pampou S, Brenner D, Garty G J Radiat Res. 2019; 61(1):68-72.

PMID: 31825079 PMC: 6976732. DOI: 10.1093/jrr/rrz074.