Safety of Ultrasound Contrast Agents in Patients with Known or Suspected Cardiac Shunts

Abstract

Contrast-enhanced ultrasound imaging is a radiation-free diagnostic tool that uses biocompatible ultrasound contrast agents (UCAs) to improve image clarity. UCAs, which do not contain dye, often salvage "technically difficult" ultrasound scans, increasing the accuracy and reliability of a front-line ultrasound diagnosis, reducing unnecessary downstream testing, lowering overall health care costs, changing therapy, and improving patient care. Two UCAs currently are approved and regulated by the US Food and Drug Administration. They have favorable safety profiles and risk/benefit ratios in adult and pediatric populations, including compromised patients with severe cardiovascular diseases. Nevertheless, these UCAs are contraindicated in patients with known or suspected right-to-left, bidirectional, or transient right-to-left cardiac shunts. These patients, who constitute 10% to 35% of the general population, typically receive no UCAs when they undergo echocardiography. If their echocardiographic images are suboptimal, they may receive inappropriate diagnosis and treatment, or they may be referred for additional diagnostic testing, including radiation-based procedures that increase their lifetime risk for cancer or procedures that use contrast agents containing dye, which may increase the risk for kidney damage. An exhaustive review of current peer-reviewed research demonstrated no scientific basis for the UCA contraindication in patients with known or suspected cardiac shunts. Initial safety concerns were based on limited rodent data and speculation related to macroaggregated albumin microspheres, a radioactive nuclear imaging agent with different physical and chemical properties and no relation to UCAs. Radioactive macroaggregated albumin is not contraindicated in adult or pediatric patients with cardiac shunts and is routinely used in these populations. In conclusion, the International Contrast Ultrasound Society Board recommends removal of the contraindication to further the public interest in safe, reliable, radiation-free diagnostic imaging options for patients with known or suspected cardiac shunts and to reduce their need for unnecessary downstream testing.

Citing Articles

Microbubble Enhanced Echocardiography in Current Cardiology Practice.

Strachinaru M, Ten Cate F Rev Cardiovasc Med. 2024; 23(6):202.

PMID: 39077192 PMC: 11283996. DOI: 10.31083/j.rcm2306202.


Microbubbles in the belly: optimizing the protocol for contrast-enhanced ultrasound of the pediatric abdomen.

Davis L, Back S Pediatr Radiol. 2022; 53(7):1224-1236.

PMID: 36006474 DOI: 10.1007/s00247-022-05464-x.


Use of Lumason Contrast Echocardiography in Post-myocardial Infarction Ventricular Septal Defect.

Cinelli M, Karam B, Spagnola J, Assaad M, Salmane C, Hoyek W Cureus. 2022; 14(7):e27128.

PMID: 36004020 PMC: 9392834. DOI: 10.7759/cureus.27128.


Surveillance of Fontan-associated liver disease: current standards and a proposal from the European Society of Paediatric Radiology Abdominal Task Force.

Perucca G, de Lange C, Franchi-Abella S, Napolitano M, Riccabona M, Kljucevsek D Pediatr Radiol. 2021; 51(13):2598-2606.

PMID: 34654967 PMC: 8599216. DOI: 10.1007/s00247-021-05173-x.


Diagnostic accuracy of contrast-enhanced ultrasound for detecting bland thrombus from inferior vena cava tumor thrombus in patients with renal cell carcinoma.

Li Q, Wang Z, Ma X, Tang J, Luo Y Int Braz J Urol. 2019; 46(1):92-100.

PMID: 31851465 PMC: 6968914. DOI: 10.1590/S1677-5538.IBJU.2019.0304.