» Articles » PMID: 23735674

Application of the Single Blood Sample Method to Estimate Feline Glomerular Filtration Rate in a Clinically Relevant Situation

Overview
Date 2013 Jun 6
PMID 23735674
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

To compare glomerular filtration rate (GFR) estimated by a single blood sample method, the non-ionic contrast medium iodixanol (40 mg I/kg) and the standard GFR tracer inulin (50 mg/kg) were co-administered as a bolus intravenous injection to 12 cats, followed by blood collection 60 and 90 mins later. Serum iodixanol and inulin concentrations were measured separately by high-performance liquid chromatography and colourimetric assay. A correlation (r = 0.90, P <0.01) was noted between GFR values estimated by the single-blood-sample method using iodixanol and inulin, indicating that this procedure can apply to feline GFR estimates, even if different GFR tracers are used. In a feline kidney transplantation study, the GFR was monitored subsequently by this simplified iodixanol method throughout a 750-day observation period with no adverse reactions. The results demonstrate that the simplified method, including the volume of distribution, can be used as an alternative or expedient tool in a clinically relevant situation.

Citing Articles

Assessment of serum symmetric dimethylarginine and creatinine concentrations in hyperthyroid cats before and after a fixed dose of orally administered radioiodine.

Yu L, Lacorcia L, Finch S, Johnstone T J Vet Intern Med. 2020; 34(4):1423-1431.

PMID: 32506701 PMC: 7379014. DOI: 10.1111/jvim.15831.


Relationship of glomerular filtration rate based on serum iodixanol clearance to IRIS staging in cats with chronic kidney disease.

Iwama R, Sato T, Katayama M, Shimamura S, Satoh H, Ichijo T J Vet Med Sci. 2015; 77(8):1033-5.

PMID: 25864431 PMC: 4565809. DOI: 10.1292/jvms.14-0494.

References
1.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

2.
Katayama R, Yamaguchi N, Yamashita T, Watanabe S, Satoh H, Yamagishi N . Calculation of glomerular filtration rate in conscious rats by the use of a bolus injection of iodixanol and a single blood sample. J Pharmacol Toxicol Methods. 2009; 61(1):59-64. DOI: 10.1016/j.vascn.2009.10.002. View

3.
Kishimoto M, Yamada K, Tsuneda R, Shimizu J, Iwasaki T, Miyake Y . Effect of contrast media formulation on computed tomography angiographic contrast enhancement. Vet Radiol Ultrasound. 2008; 49(3):233-7. DOI: 10.1111/j.1740-8261.2008.00356.x. View

4.
Bland J, Altman D . Measuring agreement in method comparison studies. Stat Methods Med Res. 1999; 8(2):135-60. DOI: 10.1177/096228029900800204. View

5.
Miyamoto K . Clinical application of plasma clearance of iohexol on feline patients. J Feline Med Surg. 2002; 3(3):143-7. PMC: 10845369. DOI: 10.1053/jfms.2001.0125. View