» Articles » PMID: 23525615

Activated Partial Thromboplastin Time and Anti-xa Measurements in Heparin Monitoring: Biochemical Basis for Discordance

Overview
Specialty Pathology
Date 2013 Mar 26
PMID 23525615
Citations 27
Authors
Affiliations
Soon will be listed here.
Abstract

We examined the concordance of heparin levels measured by a chromogenic anti-Xa assay and the activated partial thromboplastin time (APTT) during unfractionated heparin therapy (UFH) and the biochemical basis for differences between these measures. We also investigated the endogenous thrombin potential (ETP) as a possible measure of anticoagulation. Paired measures of anti-Xa and APTT were performed on 569 samples from 149 patients on UFH. The anti-Xa values and the APTT were concordant in only 54% of measurements. One hundred twelve samples from 59 patients on UFH were assayed for APTT, anti-Xa, factor II, factor VIII, and ETP. Supratherapeutic APTT values but therapeutic anti-Xa results had decreased factor II activity. Subtherapeutic APTT but therapeutic anti-Xa values had high factor VIII activity. ETP correlated with anticoagulation status and UFH dose. In conclusion, factor II and VIII activity contributes to discordance between APTT and anti-Xa results. ETP measurements may provide an additional assessment of anticoagulation status.

Citing Articles

Troubleshooting heparin resistance.

Maier C, Connors J, Levy J Hematology Am Soc Hematol Educ Program. 2024; 2024(1):186-191.

PMID: 39643992 PMC: 11665620. DOI: 10.1182/hematology.2024000659.


Early thrombus detection in the extracorporeal membrane oxygenation circuit by noninvasive real-time ultrasonic sensors.

Rim G, Hyun K, Cho D, Lim Z, Lee B, Kim K Sci Rep. 2024; 14(1):10438.

PMID: 38714704 PMC: 11076605. DOI: 10.1038/s41598-024-59873-z.


Variation in coagulation factor activity levels cause discrepancies between activated partial thromboplastin time and anti-Xa activity for heparin monitoring: a retrospective observational study.

Saito T, Hayakawa M, Kumano O, Honma Y, Murashita M, Kato J J Intensive Care. 2023; 11(1):54.

PMID: 37974289 PMC: 10652491. DOI: 10.1186/s40560-023-00701-3.


Anticoagulation Monitoring with Activated Partial ThromboPlastin Time and Anti-Xa Activity in Intensive Care Unit Patients: Interest of Thrombin Generation Assay.

Billoir P, Elie T, Levy J, Besnier E, Dureuil B, Veber B Int J Mol Sci. 2022; 23(19).

PMID: 36232517 PMC: 9570449. DOI: 10.3390/ijms231911219.


Validation of high concentrated thrombin time assay for unfractionated heparin monitoring.

Apipongrat D, Police P, Lamool R, Butthep P, Chantkran W J Clin Lab Anal. 2022; 36(10):e24695.

PMID: 36099012 PMC: 9550976. DOI: 10.1002/jcla.24695.