» Articles » PMID: 23455308

18F-FDG PET/CT Evaluation of Children and Young Adults with Suspected Spinal Fusion Hardware Infection

Overview
Journal Pediatr Radiol
Specialty Pediatrics
Date 2013 Mar 5
PMID 23455308
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Evaluation of the child with spinal fusion hardware and concern for infection is challenging because of hardware artifact with standard imaging (CT and MRI) and difficult physical examination. Studies using (18)F-FDG PET/CT combine the benefit of functional imaging with anatomical localization.

Objective: To discuss a case series of children and young adults with spinal fusion hardware and clinical concern for hardware infection. These people underwent FDG PET/CT imaging to determine the site of infection.

Materials And Methods: We performed a retrospective review of whole-body FDG PET/CT scans at a tertiary children's hospital from December 2009 to January 2012 in children and young adults with spinal hardware and suspected hardware infection. The PET/CT scan findings were correlated with pertinent clinical information including laboratory values of inflammatory markers, postoperative notes and pathology results to evaluate the diagnostic accuracy of FDG PET/CT. An exempt status for this retrospective review was approved by the Institution Review Board.

Results: Twenty-five FDG PET/CT scans were performed in 20 patients. Spinal fusion hardware infection was confirmed surgically and pathologically in six patients. The most common FDG PET/CT finding in patients with hardware infection was increased FDG uptake in the soft tissue and bone immediately adjacent to the posterior spinal fusion rods at multiple contiguous vertebral levels. Noninfectious hardware complications were diagnosed in ten patients and proved surgically in four. Alternative sources of infection were diagnosed by FDG PET/CT in seven patients (five with pneumonia, one with pyonephrosis and one with superficial wound infections).

Conclusion: FDG PET/CT is helpful in evaluation of children and young adults with concern for spinal hardware infection. Noninfectious hardware complications and alternative sources of infection, including pneumonia and pyonephrosis, can be diagnosed. FDG PET/CT should be the first-line cross-sectional imaging study in patients with suspected spinal hardware infection. Because pneumonia was diagnosed as often as spinal hardware infection, initial chest radiography should also be performed.

Citing Articles

A practical approach to interpretation of F-fluorodeoxyglucose positron emission tomography/computed tomography for postoperative spine infection.

Kloiber R, Lafford H, Koslowsky I, Tchajkov I, Rabin H Skeletal Radiol. 2023; 53(4):741-752.

PMID: 37867181 DOI: 10.1007/s00256-023-04474-6.


SPECT/CT, PET/CT and PET/MRI: oncologic and infectious applications and protocol considerations.

Voss S Pediatr Radiol. 2023; 53(7):1443-1453.

PMID: 36899268 DOI: 10.1007/s00247-023-05597-7.


The Diagnosis and Management of Pediatric Spine Infections.

Saleh E, Vasileff C, Omari A, Khalil J Cureus. 2021; 13(7):e16748.

PMID: 34345570 PMC: 8323075. DOI: 10.7759/cureus.16748.


Diagnostic performance of F-FDG PET/CT in patients with spinal infection: a systematic review and a bivariate meta-analysis.

Treglia G, Pascale M, Lazzeri E, van der Bruggen W, Delgado Bolton R, Glaudemans A Eur J Nucl Med Mol Imaging. 2019; 47(5):1287-1301.

PMID: 31729539 DOI: 10.1007/s00259-019-04571-6.


Joint EANM/ESNR and ESCMID-endorsed consensus document for the diagnosis of spine infection (spondylodiscitis) in adults.

Lazzeri E, Bozzao A, Cataldo M, Petrosillo N, Manfre L, Trampuz A Eur J Nucl Med Mol Imaging. 2019; 46(12):2464-2487.

PMID: 31399800 DOI: 10.1007/s00259-019-04393-6.


References
1.
Kamel E, Burger C, Buck A, von Schulthess G, Goerres G . Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner. Eur Radiol. 2003; 13(4):724-8. DOI: 10.1007/s00330-002-1564-2. View

2.
De Winter F, Gemmel F, Van de Wiele C, Poffijn B, Uyttendaele D, Dierckx R . 18-Fluorine fluorodeoxyglucose positron emission tomography for the diagnosis of infection in the postoperative spine. Spine (Phila Pa 1976). 2003; 28(12):1314-9. DOI: 10.1097/01.BRS.0000065483.07790.34. View

3.
Stumpe K, Dazzi H, Schaffner A, von Schulthess G . Infection imaging using whole-body FDG-PET. Eur J Nucl Med. 2000; 27(7):822-32. DOI: 10.1007/s002590000277. View

4.
Gemmel F, Rijk P, Collins J, Parlevliet T, Stumpe K, Palestro C . Expanding role of 18F-fluoro-D-deoxyglucose PET and PET/CT in spinal infections. Eur Spine J. 2010; 19(4):540-51. PMC: 2899827. DOI: 10.1007/s00586-009-1251-y. View

5.
Paik J, Lee K, Choe Y, Choi Y, Kim B . Augmented 18F-FDG uptake in activated monocytes occurs during the priming process and involves tyrosine kinases and protein kinase C. J Nucl Med. 2004; 45(1):124-8. View