» Articles » PMID: 23318391

Simultaneous Couch and Gantry Dynamic Arc Rotation (CG-Darc) in the Treatment of Breast Cancer with Accelerated Partial Breast Irradiation (APBI): a Feasibility Study

Overview
Date 2013 Jan 16
PMID 23318391
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study was to compare the dosimetry of CG-Darc with three-dimensional conformal radiation therapy (3D CRT) and volumetric-modulated arc therapy (RapidArc) in the treatment of breast cancer with APBI. CG-Darc plans were generated using two tangential couch arcs combined with a simultaneous noncoplanar gantry arc. The dynamic couch arc was modeled by consecutive IMRT fields at 10° intervals. RapidArc plans used a single partial arc with an avoidance sector, preventing direct beam exit into the thorax. CG-Darc and RapidArc plans were compared with 3D CRT in 20 patients previously treated with 3D CRT (group A), and in 15 additional patients who failed the dosimetric constraints of the Canadian trial and of NSABP B-39/RTOG 0413 for APBI (group B). CG-Darc resulted in superior target coverage compared to 3D CRT and RapidArc (V95%: 98.2% vs. 97.1% and 95.7%). For outer breast lesions, CG-Darc and RapidArc significantly reduced the ipsilateral breast V50% by 8% in group A and 15% in group B (p < 0.05) as compared with 3D CRT. For inner and centrally located lesions, CG-Darc resulted in significant ipsilateral lung V10% reduction when compared to 3D CRT and RapidArc (10.7% vs. 12.6% and 20.7% for group A, and 15.1% vs. 25.2% and 27.3% for group B). Similar advantage was observed in the dosimetry of contralateral breast where the percent maximum dose for CG-Darc, 3D CRT, and RapidArc were 3.9%, 6.3%, and 5.8% for group A and 4.3%, 9.2%, and 6.3% for group B, respectively (p < 0.05). CG-Darc achieved superior target coverage while decreasing normal tissue dose even in patients failing APBI dose constraints. Consequently, this technique has the potential of expanding the use of APBI to patients currently ineligible for such treatment. Modification of the RapidArc algorithm will be necessary to link couch and gantry rotation with variable dose rate and, therefore, enable the use of CG-Darc in clinical practice.

Citing Articles

SBRT of ventricular tachycardia using 4pi optimized trajectories.

Reis C, Little B, MacDonald R, Syme A, Thomas C, Robar J J Appl Clin Med Phys. 2021; 22(12):72-86.

PMID: 34679247 PMC: 8664144. DOI: 10.1002/acm2.13454.


Comparison of non-coplanar optimization of static beams and arc trajectories for intensity-modulated treatments of meningioma cases.

Ventura T, Rocha H, da Costa Ferreira B, Dias J, do Carmo Lopes M Phys Eng Sci Med. 2021; 44(4):1273-1283.

PMID: 34618329 PMC: 8668856. DOI: 10.1007/s13246-021-01061-8.


Verification of the delivered patient radiation dose for non-coplanar beam therapy.

Kutuzov I, Van Beek T, McCurdy B J Appl Clin Med Phys. 2021; 22(7):110-120.

PMID: 34021713 PMC: 8292689. DOI: 10.1002/acm2.13280.


Comparison of conventional and advanced radiotherapy techniques for left-sided breast cancer after breast conserving surgery.

Xie Y, Bourgeois D, Guo B, Zhang R Med Dosim. 2020; 45(4):e9-e16.

PMID: 32646715 PMC: 7609481. DOI: 10.1016/j.meddos.2020.05.004.


Dosimetric benefits of gantry-static couch-motion (GsCM) technique for breast boost radiation therapy: Reduced dose to organs-at-risk and improved dosimetric indices.

Gill G, Jakubovic R, Baker J, Button T, Chang J J Appl Clin Med Phys. 2020; 21(9):71-81.

PMID: 32627294 PMC: 7497924. DOI: 10.1002/acm2.12969.


References
1.
Paddick I . A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note. J Neurosurg. 2001; 93 Suppl 3:219-22. DOI: 10.3171/jns.2000.93.supplement. View

2.
Leonard C, Carter D, Kercher J, Howell K, Henkenberns P, Tallhamer M . Prospective trial of accelerated partial breast intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys. 2007; 67(5):1291-8. DOI: 10.1016/j.ijrobp.2006.11.016. View

3.
Shaitelman S, Kim L, Yan D, Martinez A, Vicini F, Grills I . Continuous arc rotation of the couch therapy for the delivery of accelerated partial breast irradiation: a treatment planning analysis. Int J Radiat Oncol Biol Phys. 2010; 80(3):771-8. DOI: 10.1016/j.ijrobp.2010.03.004. View

4.
Hepel J, Tokita M, MacAusland S, Evans S, Hiatt J, Price L . Toxicity of three-dimensional conformal radiotherapy for accelerated partial breast irradiation. Int J Radiat Oncol Biol Phys. 2009; 75(5):1290-6. DOI: 10.1016/j.ijrobp.2009.01.009. View

5.
Recht A, Ancukiewicz M, El-Din M, Lu X, Martin C, Berman S . Lung dose-volume parameters and the risk of pneumonitis for patients treated with accelerated partial-breast irradiation using three-dimensional conformal radiotherapy. J Clin Oncol. 2009; 27(24):3887-93. DOI: 10.1200/JCO.2008.20.0121. View