Impact of Volumetric Modulated Arc Therapy Technique on Treatment with Partial Breast Irradiation

Overview
Specialties Oncology
Radiology
Date 2010 May 7
PMID 20444558
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate the technical feasibility of volumetric modulated arc therapy (V-MAT) in the delivery of partial breast irradiation (PBI).

Methods And Materials: V-MAT and the standard, three-dimensional conformal radiotherapy (3D-CRT), were compared retrospectively in 8 patients previously treated with PBI. These patients' plans were replanned with a single partial arc using V-MAT that included partial blocking to minimize normal tissue dose. Dosimetric parameters were calculated to evaluate plan quality. Quality assurance studies included verifying both the point and the multiple planar doses. Total monitor units and delivery time were also evaluated, and collision clearance was analyzed.

Results: Volumes of ipsilateral lung irradiated to 10 Gy (V10) and 20 Gy (V20) by V-MAT were significantly less than those of 3D-CRT (p = 0.03 for V10 and p = 0.025 for V20). The volume of ipsilateral breast irradiated to 5 Gy was significantly less by using V-MAT than with 3D-CRT (p = 0.02), with a ratio of integrated dose of <1.00. The total mean monitor units (489 +/- 38) for V-MAT were significantly less than those for 3D-CRT (634 +/- 123) (p = 0.017), with a 23% reduction. The average machine delivery time was 1.21 +/- 0.10 min for the V-MAT plans and 6.28 +/- 1.40 min for the 3D-CRT plans, resulting in a reduction factor of 80.1%. The conformity indexes were 1.3 in the V-MAT plans and 1.5 in the 3D-CRT plans (p = 0.102).

Conclusions: V-MAT technology is feasible for PBI patients. Compared to a conventional 3D-CRT technique, it is more efficient, offers equivalent or better dose conformity, delivers lower doses to the ipsilateral lung and breast, and may potentially reduce intrafractional motion.

Citing Articles

Intensity Modulated Therapy for Patients With Breast Cancer. Practical Guidelines and Tips for an Effective Treatment Planning Strategy.

Fogliata A, Burger H, Groenewald A, Punt L, Parkes J, Cozzi L Adv Radiat Oncol. 2024; 9(8):101535.

PMID: 38993192 PMC: 11233865. DOI: 10.1016/j.adro.2024.101535.


Dosimetric Comparision of Coplanar versus Noncoplanar Volumetric Modulated Arc Therapy for Treatment of Bilateral Breast Cancers.

Bharati A, Rath S, Khurana R, Rastogi M, Mandal S, Gandhi A J Med Phys. 2023; 48(3):252-258.

PMID: 37969151 PMC: 10642589. DOI: 10.4103/jmp.jmp_36_23.


Flattening Filter-Free Volumetric-Modulated Arc Radiotherapy for Left-Sided Whole-Breast, Partial-Breast, and Postmastectomy Irradiations.

Zhang R, Xie Y, DiTusa C, Ohler R, Heins D, Bourgeois D J Med Phys. 2022; 47(2):166-172.

PMID: 36212208 PMC: 9542989. DOI: 10.4103/jmp.jmp_146_21.


Feasibility of 4D VMAT-CT.

Zhao X, Zhang R Biomed Phys Eng Express. 2022; 8(6).

PMID: 36206726 PMC: 9629170. DOI: 10.1088/2057-1976/ac9848.


Knowledge-Based Volumetric Modulated Arc Therapy Treatment Planning for Breast Cancer.

Apaza Blanco O, Almada M, Garcia Andino A, Zunino S, Venencia D J Med Phys. 2022; 46(4):334-340.

PMID: 35261504 PMC: 8853452. DOI: 10.4103/jmp.JMP_51_21.