Influence of Finish Line in the Distribution of Stress Trough an All Ceramic Implant-supported Crown.: A 3D Finite Element Analysis

Overview
Specialty Dentistry
Date 2013 Jan 4
PMID 23285359
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The aim of this study was to evaluate, by finite element analysis (FEA), the influence of finish line on stress distribution and resistance to the loads of a ZrO(2) crown and porcelain in implant-supported.

Material And Methods: The object of this analysis consisted of a fxture, an abutment, a passing screw, a layer of cement, a framework crown, a feldspatic porcelain veneering. The abutment's marginal design was used in 3 different types of preparation: feather edge, slight chamfer and 50°, each of them was of 1 mm depth over the entire circumference. The ZrO(2)Y-TZP coping was 0.6 mm thick. Two material matching for the abutment and the framework was used for the simulations: ZrO(2) framework and ZrO(2) abutment, ZrO(2) framework and T abutment. A 600 N axial force distributed over the entire surface of the crown was applied. The numerical simulations with finite elements were used to verify the different distribution of equivalent von Mises stress for three different geometries of abutment and framework.

Results: Slight chamfer on the matching ZrO(2) - ZrO(2) is the geometry with minimum equivalent stress of von Mises. Even for T abutment and ZrO(2) framework slight chamfer is the best configuration to minimize the localized stress. Geometry that has the highest average stress is one with abutment at 50°, we see a downward trend for all three configurations using only zirconium for both components.

Conclusions: Finite element analysis. performed for the manifacturing of implant-supported crown, gives exact geometric guide lines about the choice of chamfer preparation, while the analysis of other marginal geometries suggests a possible improved behavior of the mating between ZrO(2) abutment and ZrO(2) coping. for three different geometries of the abutment and the coping.

Citing Articles

[Compressive stress in three types of finishing lines with lithium disilicate crowns in permanent teeth: finite element analysis].

Yanapa Marquez J, Chavez-Mendez M Rev Cient Odontol (Lima). 2024; 12(1):e182.

PMID: 39015314 PMC: 11247469. DOI: 10.21142/2523-2754-1201-2024-182.


Stress Distribution within the Peri-Implant Bone for Different Implant Materials Obtained by Digital Image Correlation.

Matta R, Berger L, Loehlein M, Leven L, Taxis J, Wichmann M Materials (Basel). 2024; 17(9).

PMID: 38730967 PMC: 11085640. DOI: 10.3390/ma17092161.


Static and dynamic stress analysis of different crown materials on a titanium base abutment in an implant-supported single crown: a 3D finite element analysis.

Deste Gokay G, Oyar P, Gokcimen G, Durkan R BMC Oral Health. 2024; 24(1):545.

PMID: 38730391 PMC: 11088090. DOI: 10.1186/s12903-024-04328-0.


Effect of restoration material on marginal bone resorption around modified anatomic zirconia dental implants: A randomised controlled trial.

Aldebes A, Al-Khanati N, Nassar J, Kharboutly N, Aldamman F Ann Med Surg (Lond). 2022; 80:104313.

PMID: 36045765 PMC: 9422372. DOI: 10.1016/j.amsu.2022.104313.


Comparative finite element analysis of mandibular posterior single zirconia and titanium implants: a 3-dimensional finite element analysis.

Choi S, Choi H, Lee D, Hong M J Adv Prosthodont. 2022; 13(6):396-407.

PMID: 35003555 PMC: 8712109. DOI: 10.4047/jap.2021.13.6.396.


References
1.
Degidi M, Artese L, Scarano A, Perrotti V, Gehrke P, Piattelli A . Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in peri-implant soft tissues around titanium and zirconium oxide healing caps. J Periodontol. 2006; 77(1):73-80. DOI: 10.1902/jop.2006.77.1.73. View

2.
Scarano A, Piattelli M, Caputi S, Favero G, Piattelli A . Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. J Periodontol. 2004; 75(2):292-6. DOI: 10.1902/jop.2004.75.2.292. View

3.
Vult von Steyern P, Carlson P, Nilner K . All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil. 2005; 32(3):180-7. DOI: 10.1111/j.1365-2842.2004.01437.x. View

4.
Denry I, Kelly J . State of the art of zirconia for dental applications. Dent Mater. 2007; 24(3):299-307. DOI: 10.1016/j.dental.2007.05.007. View

5.
Piwowarczyk A, Ottl P, Lauer H, Kuretzky T . A clinical report and overview of scientific studies and clinical procedures conducted on the 3M ESPE Lava All-Ceramic System. J Prosthodont. 2005; 14(1):39-45. DOI: 10.1111/j.1532-849X.2005.00003.x. View