» Articles » PMID: 23265804

Enhanced Detection of Open-angle Glaucoma with an Anatomically Accurate Optical Coherence Tomography-derived Neuroretinal Rim Parameter

Overview
Journal Ophthalmology
Publisher Elsevier
Specialty Ophthalmology
Date 2012 Dec 26
PMID 23265804
Citations 161
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Neuroretinal rim assessment based on the clinical optic disc margin (DM) lacks a sound anatomic basis for 2 reasons: (1) The DM is not reliable as the outer border of rim tissue because of clinically and photographically invisible extensions of Bruch's membrane (BM) inside the DM and (2) nonaccountability of rim tissue orientation in the optic nerve head (ONH). The BM opening-minimum rim width (BMO-MRW) is a parameter that quantifies the rim from its true anatomic outer border, BMO, and accounts for its variable orientation. We report the diagnostic capability of BMO-MRW.

Design: Case control.

Participants: Patients with open-angle glaucoma (n = 107) and healthy controls (n = 48).

Methods: Spectral-domain optical coherence tomography (SD-OCT) with 24 radial and 1 circumpapillary B-scans, centered on the ONH, and confocal scanning laser tomography (CSLT) were performed. The internal limiting membrane (ILM) and BMO were manually segmented in each radial B-scan. Three SD-OCT parameters were computed globally and sectorally: (1) circumpapillary retinal nerve fiber layer thickness (RNFLT); (2) BMO-horizontal rim width (BMO-HRW), the distance between BMO and ILM in the BMO reference plane; and (3) BMO-MRW, the minimum distance between BMO and ILM. Moorfields Regression Analysis (MRA) with CLST was performed globally and sectorally to yield MRA1 and MRA2, where "borderline" was classified as normal and abnormal, respectively.

Main Outcome Measures: Sensitivity, specificity, and likelihood ratios (LRs) for positive and negative test results (LR+/LR-).

Results: The median (interquartile range) age and mean deviation of patients and controls were 69.9 (64.3-76.9) and 65.0 (58.1-74.3) years and -3.92 (-7.87 to -1.62) and 0.33 (-0.32 to 0.98) dB, respectively. Globally, BMO-MRW yielded better diagnostic performance than the other parameters. At 95% specificity, the sensitivity of RNFLT, BMO-HRW, and BMO-MRW was 70%, 51%, and 81%, respectively. The corresponding LR+/LR- was 14.0/0.3, 10.2/0.5, and 16.2/0.2. Sectorally, at 95% specificity, the sensitivity of RNFLT ranged from 31% to 59%, of BMO-HRW ranged from 35% to 64%, and of BMO-MRW ranged from 54% to 79%. Globally and in all sectors, BMO-MRW performed better than MRA1 or MRA2.

Conclusions: The higher sensitivity at 95% specificity in early glaucoma of BMO-MRW compared with current BMO methods is significant, indicating a new structural marker for the detection and risk profiling of glaucoma.

Citing Articles

The performance of optic disc-macula distance to disc-diameter ratio in qualitative and quantitative assessment of the optic disc size.

Ishikawa A, Kusaka K, Nakanishi A, Yokoyama Y Eye (Lond). 2024; .

PMID: 39643719 DOI: 10.1038/s41433-024-03540-0.


Sources of Discrepancy between Retinal Nerve Fiber Layer and Bruch's Membrane Opening-Minimum Rim Width Thickness in Eyes with Glaucoma.

Zhuang I, Ashrafkhorasani M, Mohammadzadeh V, Nouri-Mahdavi K Ophthalmol Sci. 2024; 5(1):100601.

PMID: 39411541 PMC: 11474368. DOI: 10.1016/j.xops.2024.100601.


Acute effects of swimming goggle wearing on intraocular pressure, anterior chamber biometrics, and optic nerve head morphology.

Bilici S, Toprak A, Koru-Toprak M, Ugurbas S Sci Rep. 2024; 14(1):23339.

PMID: 39375418 PMC: 11458763. DOI: 10.1038/s41598-024-73990-9.


Differences and Similarities Between Primary Open Angle Glaucoma and Primary Angle-Closure Glaucoma.

Wang Y, Guo Y, Zhang Y, Huang S, Zhong Y Eye Brain. 2024; 16:39-54.

PMID: 39309574 PMC: 11416111. DOI: 10.2147/EB.S472920.


Automatic retinal image analysis methods using colour fundus images for screening glaucomatous optic neuropathy.

Shi C, Lee J, Shi D, Wang G, Yuan F, Zee B BMJ Open Ophthalmol. 2024; 9(1).

PMID: 39256168 PMC: 11429265. DOI: 10.1136/bmjophth-2023-001594.


References
1.
Mwanza J, Chang R, Budenz D, Durbin M, Gendy M, Shi W . Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with cirrus HD-OCT in glaucomatous eyes. Invest Ophthalmol Vis Sci. 2010; 51(11):5724-30. PMC: 3061508. DOI: 10.1167/iovs.10-5222. View

2.
Pablo L, Ferreras A, Fogagnolo P, Figus M, Pajarin A . Optic nerve head changes in early glaucoma: a comparison between stereophotography and Heidelberg retina tomography. Eye (Lond). 2009; 24(1):123-30. DOI: 10.1038/eye.2009.14. View

3.
Abrams L, Scott I, Spaeth G, Quigley H, Varma R . Agreement among optometrists, ophthalmologists, and residents in evaluating the optic disc for glaucoma. Ophthalmology. 1994; 101(10):1662-7. DOI: 10.1016/s0161-6420(94)31118-3. View

4.
Langenegger S, Funk J, Toteberg-Harms M . Reproducibility of retinal nerve fiber layer thickness measurements using the eye tracker and the retest function of Spectralis SD-OCT in glaucomatous and healthy control eyes. Invest Ophthalmol Vis Sci. 2011; 52(6):3338-44. DOI: 10.1167/iovs.10-6611. View

5.
Reis A, Sharpe G, Yang H, Nicolela M, Burgoyne C, Chauhan B . Optic disc margin anatomy in patients with glaucoma and normal controls with spectral domain optical coherence tomography. Ophthalmology. 2012; 119(4):738-47. PMC: 3319857. DOI: 10.1016/j.ophtha.2011.09.054. View