» Articles » PMID: 23233266

Simultaneous Analysis of Multiple Monoclonal Antibody Biotherapeutics by LC-MS/MS Method in Rat Plasma Following Cassette-dosing

Overview
Journal AAPS J
Specialty Pharmacology
Date 2012 Dec 13
PMID 23233266
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

We have recently developed a general liquid chromatography-tandem mass spectrometric (LC-MS/MS) method using a stable isotope-labeled (SIL) monoclonal antibody (mAb) as an internal standard (IS) for single-analyte quantification of mAb (Li et al. Anal Chem 84(3):1267-1273, 2012). The method offers an advantage over ligand binding assay in reducing the time and resources needed for bioanalytical support in preclinical stages of drug development. In this paper, we report another marked increase in assay efficiency for multi-analyte bioanalysis using unique surrogate peptides for each analyte and the strategic choice of the SIL-IS peptide. The method was qualified for the simultaneous determinations of four mAbs in rat plasma and applied to samples from discrete- and cassette-dosed rats. The pharmacokinetic parameters of the four mAbs of cassette dosing were comparable to those of discrete dosing and of enzyme-linked immunosorbent assay results. Although there may be limitations and special considerations for cassette-dosing of biologics, these results demonstrate the robust performance of the multi-analyte LC-MS/MS method allowing cassette-dosing that would ultimately reduce animal use and improve efficiency.

Citing Articles

Combination of cassette-dosing and microsampling for reduced animal usage for antibody pharmacokinetics in cynomolgus monkeys, wild-type mice, and human FcRn transgenic mice.

Nagayasu M, Ozeki K Pharm Res. 2021; 38(4):583-592.

PMID: 33782838 DOI: 10.1007/s11095-021-03028-6.


Quantification of T Cell Binding Polyclonal Rabbit Anti-thymocyte Globulin in Human Plasma with Liquid Chromatography Tandem-Mass Spectrometry.

El Amrani M, Admiraal R, Willaert L, Ebskamp-van Raaij L, Lacna A, Hack C AAPS J. 2020; 22(2):43.

PMID: 32030538 PMC: 7005072. DOI: 10.1208/s12248-020-0419-6.


Quantification of total dinutuximab concentrations in neuroblastoma patients with liquid chromatography tandem mass spectrometry.

El Amrani M, Szanto C, Hack C, Huitema A, Nierkens S, Van Maarseveen E Anal Bioanal Chem. 2018; 410(23):5849-5858.

PMID: 29938370 PMC: 6096702. DOI: 10.1007/s00216-018-1198-0.


Non-enzymolytic adenosine barcode-mediated dual signal amplification strategy for ultrasensitive protein detection using LC-MS/MS.

Yang W, Li T, Shu C, Ji S, Wang L, Wang Y Mikrochim Acta. 2018; 185(6):293.

PMID: 29748725 DOI: 10.1007/s00604-018-2832-4.


Time-Dependent Structural Alteration of Rituximab Analyzed by LC/TOF-MS after a Systemic Administration to Rats.

Otani Y, Yonezawa A, Tsuda M, Imai S, Ikemi Y, Nakagawa S PLoS One. 2017; 12(1):e0169588.

PMID: 28052138 PMC: 5215255. DOI: 10.1371/journal.pone.0169588.


References
1.
Nagilla R, Nord M, McAtee J, Jolivette L . Cassette dosing for pharmacokinetic screening in drug discovery: comparison of clearance, volume of distribution, half-life, mean residence time, and oral bioavailability obtained by cassette and discrete dosing in rats. J Pharm Sci. 2011; 100(9):3862-74. DOI: 10.1002/jps.22525. View

2.
He K, Qian M, Wong H, Bai S, He B, Brogdon B . N-in-1 dosing pharmacokinetics in drug discovery: experience, theoretical and practical considerations. J Pharm Sci. 2007; 97(7):2568-80. DOI: 10.1002/jps.21196. View

3.
Manitpisitkul P, White R . Whatever happened to cassette-dosing pharmacokinetics?. Drug Discov Today. 2004; 9(15):652-8. DOI: 10.1016/S1359-6446(04)03137-X. View

4.
Korfmacher W, Cox K, Ng K, Veals J, Hsieh Y, Wainhaus S . Cassette-accelerated rapid rat screen: a systematic procedure for the dosing and liquid chromatography/atmospheric pressure ionization tandem mass spectrometric analysis of new chemical entities as part of new drug discovery. Rapid Commun Mass Spectrom. 2001; 15(5):335-40. DOI: 10.1002/rcm.235. View

5.
Hop C, Wang Z, Chen Q, Kwei G . Plasma-pooling methods to increase throughput for in vivo pharmacokinetic screening. J Pharm Sci. 1998; 87(7):901-3. DOI: 10.1021/js970486q. View