» Articles » PMID: 23220491

Nanomaterial-based Electrochemical Biosensors for Cytochrome C Using Cytochrome C Reductase

Overview
Publisher Elsevier
Specialty Biochemistry
Date 2012 Dec 11
PMID 23220491
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Emerging evidences have pointed out that the release of cytochrome c (cyt c) from mitochondria into cytosol is a critical step in the activation of apoptosis. This article presents a novel approach for the detection of mitochondrial cyt c release for the first time using cytochrome c reductase (CcR) immobilized on nanoparticles decorated electrodes. Two kinds of nanomaterial-based biosensor platforms were used: (a) carbon nanotubes (CNT) incorporated polypyrrole (PPy) matrix on Pt electrode and (b) self-assembled monolayer (SAM) functionalized gold nanoparticles (GNP) in PPy-Pt. Scanning electron microscope was used to characterize the surface morphologies of the nanomaterial modified electrodes. Cyclic voltammograms of both the biosensors showed reversible redox peaks at -0.45 and -0.34 V vs Ag/AgCl, characteristic of CcR. In comparison, the CcR-CNT biosensor gave a detection limit of 0.5±0.03 μM cyt c, which was 4-fold better than the CcR-GNP biosensor (2±0.03 μM). Moreover, the CcR-CNT biosensor achieved a much larger linear range (1-1000 μM) over the CcR-GNP biosensor (5-600 μM) with 2-fold better sensitivity. The CcR-CNT-PPy-Pt biosensor was further applied to quantify the mitochondrial cyt c released in cytosol of A549 cells upon induction of apoptosis with doxorubicin, the results agreed well with standard western blot analysis.

Citing Articles

Cytochrome c in cancer therapy and prognosis.

Pessoa J Biosci Rep. 2022; 42(12).

PMID: 36479932 PMC: 9780037. DOI: 10.1042/BSR20222171.


Fabrication of a label-free electrochemical aptasensor to detect cytochrome c in the early stage of cell apoptosis.

Sadrabadi E, Benvidi A, Yazdanparast S, Amiri-Zirtol L Mikrochim Acta. 2022; 189(8):279.

PMID: 35829926 DOI: 10.1007/s00604-022-05373-8.


Nanozymes in Point-of-Care Diagnosis: An Emerging Futuristic Approach for Biosensing.

Das B, Franco J, Logan N, Balasubramanian P, Kim M, Cao C Nanomicro Lett. 2021; 13(1):193.

PMID: 34515917 PMC: 8438099. DOI: 10.1007/s40820-021-00717-0.


Aptamer-based colorimetric determination of early-stage apoptotic cells via the release of cytochrome c from mitochondria and by exploiting silver/platinum alloy nanoclusters as a peroxidase mimic.

Borghei Y, Hosseinkhani S Mikrochim Acta. 2019; 186(12):845.

PMID: 31768654 DOI: 10.1007/s00604-019-3977-5.


Graphene- and Graphene Oxide-Based Nanocomposite Platforms for Electrochemical Biosensing Applications.

Thangamuthu M, Hsieh K, Kumar P, Chen G Int J Mol Sci. 2019; 20(12).

PMID: 31216691 PMC: 6628170. DOI: 10.3390/ijms20122975.