» Articles » PMID: 23185567

Acute Variations in Retinal Vascular Oxygen Content in a Rabbit Model of Retinal Venous Occlusion

Overview
Journal PLoS One
Date 2012 Nov 28
PMID 23185567
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To study the variation in intravascular oxygen saturation (oximetry) during an acute retinal vein occlusion (RVO) using hyperspectral computed tomographic spectroscopy based oximetry measurements.

Methods: Thirty rabbits were dilated and anesthetized for experiments. Baseline oximetry measurements were made using a custom-made hyperspectral computed tomographic imaging spectrometer coupled to a fundus camera. RVO were induced using argon green laser following an intravenous injection of Rose Bengal. RVO induction was confirmed by fluorescein angiography. Retinal oximetry measurements were repeated in arterial and venous branches one hour after RVO induction and up to 4 weeks afterwards. Comparison of retinal oximetry before and after vein occlusion was made using the Student T-test.

Results: One hour after RVO induction, we observed statistically significant reductions in the intravascular oxygen saturation in temporal retinal arteries (85.1 ± 6.1% vs. 80.6 ± 6.6%; p<0.0001) and veins (71.4 ± 5.5% vs. 64.0 ± 4.7%; p<0.0001). This decrease was reversible in animals that spontaneously recannulated the vein occlusion. There were no statistically significant differences in oxygen saturation in the nasal control arteries and veins before and after temporal vein RVO induction.

Conclusions: We demonstrate, for the first time, acute changes in the intravascular oxygen content of retinal vessels 1 hour after RVO. These changes are reversible upon spontaneous recannulation of retinal vessels. This study demonstrates that hyperspectral computer tomographic spectroscopy based oximetry can detect physiological variations in intravascular retinal oxygen saturation. The study also provides the first qualitative and quantitative evidence of the variation in retinal vascular oxygen content directly attributable to an acute retinal vein occlusion.

Citing Articles

Hyperspectral retinal imaging biomarkers of ocular and systemic diseases.

Saeed A, Hadoux X, van Wijngaarden P Eye (Lond). 2024; 39(4):667-672.

PMID: 38778136 PMC: 11885810. DOI: 10.1038/s41433-024-03135-9.


Past, present and future role of retinal imaging in neurodegenerative disease.

Kashani A, Asanad S, Chan J, Singer M, Zhang J, Sharifi M Prog Retin Eye Res. 2021; 83:100938.

PMID: 33460813 PMC: 8280255. DOI: 10.1016/j.preteyeres.2020.100938.


Hyperspectral Imaging and the Retina: Worth the Wave?.

Lemmens S, van Eijgen J, Van Keer K, Jacob J, Moylett S, De Groef L Transl Vis Sci Technol. 2020; 9(9):9.

PMID: 32879765 PMC: 7442879. DOI: 10.1167/tvst.9.9.9.


Hyperspectral Image Mapping Spectrometry for Retinal Oximetry Measurements in Four Diseased Eyes.

Dwight J, Weng C, Coffee R, Pawlowski M, Tkaczyk T Int Ophthalmol Clin. 2016; 56(4):25-38.

PMID: 27575756 PMC: 5103700. DOI: 10.1097/IIO.0000000000000139.


A pilot study on effects of acupuncture and moxibustion by hyperspectral imaging technique.

Zhang D, Li Y, Wang S, Bai X, Song X, Li S Evid Based Complement Alternat Med. 2014; 2014:135212.

PMID: 25544851 PMC: 4269316. DOI: 10.1155/2014/135212.


References
1.
Hayreh S . Management of central retinal vein occlusion. Ophthalmologica. 2003; 217(3):167-88. DOI: 10.1159/000068980. View

2.
Hammer H, Schweitzer D, Thamm E, Kolb A, Strobel J . Scattering properties of the retina and the choroids determined from OCT-A-scans. Int Ophthalmol. 2002; 23(4-6):291-5. DOI: 10.1023/a:1014430009122. View

3.
Wankhede M, Agarwal N, Fraga-Silva R, DeDeugd C, Raizada M, Oh S . Spectral imaging reveals microvessel physiology and function from anastomoses to thromboses. J Biomed Opt. 2010; 15(1):011111. PMC: 2917463. DOI: 10.1117/1.3316299. View

4.
Mordant D, Al-Abboud I, Muyo G, Gorman A, Sallam A, Rodmell P . Validation of human whole blood oximetry, using a hyperspectral fundus camera with a model eye. Invest Ophthalmol Vis Sci. 2011; 52(5):2851-9. DOI: 10.1167/iovs.10-6217. View

5.
Cohen A, Laing R . Multiple scattering analysis of retinal blood oximetry. IEEE Trans Biomed Eng. 1976; 23(5):391-400. DOI: 10.1109/tbme.1976.324650. View