Invalidity of SUV Measurements of Lesions in Close Proximity to Hot Sources Due to "Shine-Through" Effect on FDG PET-CT Interpretation

Overview
Publisher Wiley
Specialty Radiology
Date 2012 Oct 26
PMID 23097700
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

It is well known that many technical and physiologic factors can affect the reliability of the standardized uptake value (SUV) on FDG PET-CT. Another potential problem of which we may be aware but has not been previously discussed is significant SUV overestimation of lesions in the direct neighborhood of large hot sources, namely, areas with high FDG uptake or activity such as a tumor, myocardium, urinary bladder, kidney, or gastrointestinal tract. The magnitude of SUV overestimation of the lesions directly neighboring the large hot sources is varied among the different cases, and it is possibly secondary to "shine-through" effect of the hot sources, which would warrant further systematic investigation such as phantom simulation experiment. If the lesion is in the close territory of the hot source, measured SUV is often overestimated and invalid. Visual interpretation should be used for evaluation of FDG avidity of the lesion.

Citing Articles

Shine-through artifact due to high-radioactivity bladder and bowel gas in F-FDG PET/CT: impact of time-of-flight algorithm and radioactivity concentration of urine in the bladder on the occurrence of the artifacts.

Tomita Y, Ichikawa Y, Sakuma H Ann Nucl Med. 2022; 36(8):736-745.

PMID: 35635608 DOI: 10.1007/s12149-022-01756-2.


Does the beta regularization parameter of bayesian penalized likelihood reconstruction always affect the quantification accuracy and image quality of positron emission tomography computed tomography?.

Wu Z, Guo B, Huang B, Zhao B, Qin Z, Hao X J Appl Clin Med Phys. 2021; 22(3):224-233.

PMID: 33683004 PMC: 7984479. DOI: 10.1002/acm2.13129.


Comparison of Correction Techniques for the Spill in Effect in Emission Tomography.

Akerele M, Karakatsanis N, Deidda D, Cal-Gonzalez J, Forsythe R, Dweck M IEEE Trans Radiat Plasma Med Sci. 2021; 4(4):422-432.

PMID: 33542967 PMC: 7116684. DOI: 10.1109/TRPMS.2020.2980443.


Assessment of different quantification metrics of [F]-NaF PET/CT images of patients with abdominal aortic aneurysm.

Akerele M, Mushari N, Forsythe R, Syed M, Karakatsanis N, Newby D J Nucl Cardiol. 2020; 29(1):251-261.

PMID: 32557152 PMC: 8873073. DOI: 10.1007/s12350-020-02220-2.


Validation of the physiological background correction method for the suppression of the spill-in effect near highly radioactive regions in positron emission tomography.

Akerele M, Wadhwa P, Silva-Rodriguez J, Hallett W, Tsoumpas C EJNMMI Phys. 2018; 5(1):34.

PMID: 30519974 PMC: 6281548. DOI: 10.1186/s40658-018-0233-8.


References
1.
Ueda K, Suga K, Kaneda Y, Sakano H, Tanaka T, Hayashi M . Radioisotope lymph node mapping in nonsmall cell lung cancer: can it be applicable for sentinel node biopsy?. Ann Thorac Surg. 2004; 77(2):426-30. DOI: 10.1016/S0003-4975(03)01351-1. View

2.
Wu C, Morita E, Treseler P, Esserman L, Hwang E, Kuerer H . Failure to harvest sentinel lymph nodes identified by preoperative lymphoscintigraphy in breast cancer patients. Breast J. 2003; 9(2):86-90. DOI: 10.1046/j.1524-4741.2003.09205.x. View

3.
Liu Y, Chun K, Freeman L . 'Shine through' on dual tracer parathyroid scintigraphy: a potential pitfall in interpretation. Clin Nucl Med. 2005; 30(3):145-9. DOI: 10.1097/00003072-200503000-00001. View

4.
Motomura K, Noguchi A, Hashizume T, Hasegawa Y, Komoike Y, Inaji H . Usefulness of a solid-state gamma camera for sentinel node identification in patients with breast cancer. J Surg Oncol. 2004; 89(1):12-7. DOI: 10.1002/jso.20162. View

5.
Acton P, Zhuang H, Alavi A . Quantification in PET. Radiol Clin North Am. 2004; 42(6):1055-62, viii. DOI: 10.1016/j.rcl.2004.08.010. View