Abstract

The inflatable penile prosthesis (IPP) has high patient satisfaction rates and good mechanical reliability rates in multiple studies. The number one patient compliant at six months is penile length. Recently, new technique for aggressive sizing of the cylinders has been published on in the literature. One IPP company has produced a new product that has longer length cylinders (XL) than those available. However, traditionally long cylinders were felt to lack axial rigidity. Therefore, a prospective, multicenter, central IRB-approved, monitored study was performed on the new product to address these concerns. At 2 centers, a total of 17 patients underwent surgical implantation of these new XL cylinders. These patients were questioned for patient satisfaction and tested for axial rigidity using a Fastsize Erectile Quality Monitor. The results showed excellent patient satisfaction rates and great axial rigidity with the Fastsize Erectile Quality Monitor. The XL cylinders appear to give the IPP surgeon the ability to use longer cylinders with good patient satisfaction and great axial rigidity.

Citing Articles

The clinical significance of imperfection: is idiopathic corporal asymmetry related to curvature during penile prosthesis placement?.

Bole R, Alom M, Habashy E, Ahmed M, Ziegelmann M, Kohler T Int J Impot Res. 2023; 36(8):820-824.

PMID: 36797455 DOI: 10.1038/s41443-023-00669-6.


Comparison of the patient and partner satisfaction with 700CX and Titan penile prostheses.

Romero Otero J, Rojas Cruz C, Garcia Gomez B, Geli J, Polo J, Ruiz Castane E Asian J Androl. 2016; 19(3):321-325.

PMID: 26806085 PMC: 5427788. DOI: 10.4103/1008-682X.172822.

References
1.
Sansalone S, Garaffa G, Djinovic R, Egydio P, Vespasiani G, Miano R . Simultaneous penile lengthening and penile prosthesis implantation in patients with Peyronie's disease, refractory erectile dysfunction, and severe penile shortening. J Sex Med. 2011; 9(1):316-21. DOI: 10.1111/j.1743-6109.2011.02509.x. View

2.
Scott F, BRADLEY W, Timm G . Management of erectile impotence. Use of implantable inflatable prosthesis. Urology. 1973; 2(1):80-2. DOI: 10.1016/0090-4295(73)90224-0. View

3.
Wilson S, Delk J, Mulcahy J, Cleves M, Salem E . Upsizing of inflatable penile implant cylinders in patients with corporal fibrosis. J Sex Med. 2006; 3(4):736-742. DOI: 10.1111/j.1743-6109.2006.00263.x. View

4.
Wang R, Howard G, Hoang A, Yuan J, Lin H, Dai Y . Prospective and long-term evaluation of erect penile length obtained with inflatable penile prosthesis to that induced by intracavernosal injection. Asian J Androl. 2009; 11(4):411-5. PMC: 3735309. DOI: 10.1038/aja.2009.35. View

5.
Shaeer O . Supersizing the penis following penile prosthesis implantation. J Sex Med. 2010; 7(7):2608-16. DOI: 10.1111/j.1743-6109.2010.01723.x. View