Critical Limits for Urgent Clinician Notification at US Medical Centers

Overview
Journal JAMA
Specialty General Medicine
Date 1990 Feb 2
PMID 2296127
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

A national survey determined critical limits used by trauma and medical centers in the United States. Mean low and high critical limits for the most frequently listed tests were the following values: glucose, 2.6 and 26.9 mmol/L; potassium, 2.8 and 6.2 mmol/L; calcium, 1.65 and 3.22 mmol/L; sodium, 120 and 158 mmol/L; hematocrit, 0.18 and 0.61; hemoglobin, 66 and 199 g/L; platelets, 37 x 10(9)/L and 910 X 10(9)/L; and white blood cell count, 2.0 X 10(9)/L and 37.0 X 10(9)/L. The high critical limit for prothrombin time was 27 seconds. Critical limits for PCO2 were 19 and 67 mm Hg; and for pH, 7.21 and 7.59. The low critical limit for PO2 was 43 mm Hg; no high critical limit was listed. The noncritical span for free calcium was 0.80 mmol/L. Important qualitative critical results included the presence of blasts on the blood smear, a Gram's stain or culture from blood or cerebrospinal fluid with positive results, and an elevated white blood cell count in the cerebrospinal fluid. A product of 15 years of collective medical judgment, these data should help physicians improve the quality and efficiency of acute patient care.

Citing Articles

Visualization of Critical Limits and Critical Values Facilitates Interpretation.

Shah A, Dohner J, Cheng K, Garcia M, Kost G Diagnostics (Basel). 2025; 15(5).

PMID: 40075851 PMC: 11899349. DOI: 10.3390/diagnostics15050604.


Analysis of Laboratory Critical Values During COVID-19 Pandemic at Tertiary Hospital in Saudi Arabia.

Jeraiby M Int J Gen Med. 2024; 17:367-375.

PMID: 38327817 PMC: 10849053. DOI: 10.2147/IJGM.S449505.


Termination of Repeat Testing in Chemical Laboratories Based on Practice Guidelines: Examining the Effect of Rule-Based Repeat Testing in a Transplantation Center.

Soleimani N, Azadi A, Esmaeili M, Ghodsi F, Ghahramani R, Hafezi A J Anal Methods Chem. 2021; 2021:9955990.

PMID: 34055449 PMC: 8137285. DOI: 10.1155/2021/9955990.


Necessity of Routine Repeat Testing of Critical Values in Various Working Shifts.

Saffar H, Abdollahi A, Hosseini A, Torabi Farsani M, Hajinasrollah G, Mohaghegh P Iran J Pathol. 2020; 15(3):161-166.

PMID: 32754210 PMC: 7354071. DOI: 10.30699/ijp.2020.99403.1980.


Analysis of laboratory critical values at a referral Spanish tertiary university hospital.

Arbiol-Roca A, Corral-Comesana S, Cano-Corres R, Castro-Castro M, Dastis-Arias M, Dot-Bach D Biochem Med (Zagreb). 2018; 29(1):010704.

PMID: 30591814 PMC: 6294153. DOI: 10.11613/BM.2019.010704.