Digital Storage Phosphor Imaging Versus Conventional Film Radiography in CT-documented Chest Disease

Overview
Journal Radiology
Specialty Radiology
Date 1990 Jan 1
PMID 2294549
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

The advantages of imaging the chest with digital storage phosphor radiography (SR) may be nullified by its spatial resolution, which is lower than that of conventional film radiography (FR). To test the reader detection performance with the two modalities under clinical conditions, the authors compared 140-kVp isoexposure SR (system resolution: 0.2 mm, 10 bits) and FR images of a variety of chest abnormalities proved by computed tomography (CT) (157 patients, 244 abnormalities, 5,652 observations, six readers). In all tests, SR was as good as or better than FR (P less than .05). In overall detection, indicated by the average area of receiver operating characteristics, SR and FR were equivalent. SR was superior for mediastinal lesions and for pulmonary opacities greater than 2 cm in diameter. For all other types of pulmonary lesions and pleural abnormalities, SR and FR were equivalent. Currently available commercial SR systems can replace film radiographic systems in the detection of a wide variety of chest lesions. SR is likely to enable better visualization than FR in the detection of mediastinal and large pulmonary abnormalities.

Citing Articles

Modeling the performance characteristics of computed radiography (CR) systems.

Vedantham S, Karellas A IEEE Trans Med Imaging. 2010; 29(3):790-806.

PMID: 20199915 PMC: 5228607. DOI: 10.1109/TMI.2009.2036995.


Two K versus 4 K storage phosphor chest radiography: detection performance and image quality.

Koelblinger C, Prokop M, Weber M, Sailer J, Cartes-Zumelzu F, Schaefer-Prokop C Eur Radiol. 2007; 17(11):2934-40.

PMID: 17492289 DOI: 10.1007/s00330-007-0650-x.


Diagnosis of IPA in HIV: the role of the chest X-ray and radiologist.

Zaspel U, Denning D, Lemke A, Greene R, Schurmann D, Maschmeyer G Eur Radiol. 2004; 14(11):2030-7.

PMID: 15309496 DOI: 10.1007/s00330-004-2447-5.


Interpretation of normal anatomic structures on chest radiography: comparison of Fuji computed radiography (FCR) 5501D with FCR 5000 and screen-film system.

Nakashima K, Ashizawa K, Ochi M, Hashmi R, Hayashi K, Gotoh S J Appl Clin Med Phys. 2003; 4(1):85-90.

PMID: 12540822 PMC: 5724430. DOI: 10.1120/jacmp.v4i1.2547.


Clinical evaluation of irreversible data compression for computed radiography of the chest.

Egashira K, Nakata H, Watanabe H, Uchida K, Nakamura K, Ishino Y J Digit Imaging. 1998; 11(4):176-81.

PMID: 9848050 PMC: 3453153. DOI: 10.1007/BF03178080.