Component malalignment can be associated with pain following total knee replacement (TKR). Using MRI, we reviewed 50 patients with painful TKRs and compared them with a group of 16 asymptomatic controls to determine the feasibility of using MRI in evaluating the rotational alignment of the components. Using the additional soft-tissue detail provided by this modality, we also evaluated the extent of synovitis within these two groups. Angular measurements were based on the femoral transepicondylar axis and tibial tubercle. Between two observers, there was very high interobserver agreement in the measurements of all values. Patients with painful TKRs demonstrated statistically significant relative internal rotation of the femoral component (p = 0.030). There was relative internal rotation of the tibial to femoral component and combined excessive internal rotation of the components in symptomatic knees, although these results were significant only with one of the observers (p = 0.031). There was a statistically significant association between the presence and severity of synovitis and painful TKR (p < 0.001). MRI is an effective modality in evaluating component rotational alignment.

Citing Articles

Curve-on-curve technique is more reliable than free-floating technique for tibial components positioning in posterior stabilized total knee arthroplasty using symmetrical tibial components in varus osteoarthritis.

Elkabbani M, Saied A, Abouelnas B, Dragos A, Osman A, Tarabichi S BMC Musculoskelet Disord. 2024; 25(1):1009.

PMID: 39668343 PMC: 11636221. DOI: 10.1186/s12891-024-07975-0.


Anatomical Reference of the Femur after Distal Resection Is Reliable for Rotational Alignment in Total Knee Arthroplasty.

Kim S, Park Y, Choi G, Lee H J Pers Med. 2024; 14(6).

PMID: 38929884 PMC: 11204464. DOI: 10.3390/jpm14060663.


Accuracy of Femoral Component External Rotation with all Burr Robotic Assisted Total Knee Arthroplasty.

Laddha M, Gowtam S, Jain P Malays Orthop J. 2024; 18(1):19-25.

PMID: 38638660 PMC: 11023343. DOI: 10.5704/MOJ.2403.003.


Combined femoral and tibial component total knee arthroplasty device rotation measurement is reliable and predicts clinical outcome.

Hernandez-Hermoso J, Nescolarde L, Yanez-Siller F, Calle-Garcia J, Garcia-Perdomo D, Perez-Andres R J Orthop Traumatol. 2023; 24(1):40.

PMID: 37535276 PMC: 10400495. DOI: 10.1186/s10195-023-00718-2.


Perineural local anesthetic treatments for osteoarthritic pain.

Knight B, Walker J, Nair L Regen Eng Transl Med. 2022; 7(3):262-282.

PMID: 36275437 PMC: 9585910. DOI: 10.1007/s40883-021-00223-0.