» Articles » PMID: 22884967

Shear Strength Behavior of Human Trabecular Bone

Overview
Journal J Biomech
Specialty Physiology
Date 2012 Aug 14
PMID 22884967
Citations 21
Authors
Affiliations
Soon will be listed here.
Abstract

The shear strength of human trabecular bone may influence overall bone strength under fall loading conditions and failure at bone-implant interfaces. Here, we sought to compare shear and compressive yield strengths of human trabecular bone and elucidate the underlying failure mechanisms. We analyzed 54 specimens (5-mm cubes), all aligned with the main trabecular orientation and spanning four anatomic sites, 44 different cadavers, and a wide range of bone volume fraction (0.06-0.38). Micro-CT-based non-linear finite element analysis was used to assess the compressive and shear strengths and the spatial distribution of yielded tissue; the tissue-level constitutive model allowed for kinematic non-linearity and yielding with strength asymmetry. We found that the computed values of both the shear and compressive strengths depended on bone volume fraction via power law relations having an exponent of 1.7 (R(2)=0.95 shear; R(2)=0.97 compression). The ratio of shear to compressive strengths (mean±SD, 0.44±0.16) did not depend on bone volume fraction (p=0.24) but did depend on microarchitecture, most notably the intra-trabecular standard deviation in trabecular spacing (R(2)=0.23, p<0.005). For shear, the main tissue-level failure mode was tensile yield of the obliquely oriented trabeculae. By contrast, for compression, specimens having low bone volume fraction failed primarily by large-deformation-related tensile yield of horizontal trabeculae and those having high bone volume failed primarily by compressive yield of vertical trabeculae. We conclude that human trabecular bone is generally much weaker in shear than compression at the apparent level, reflecting different failure mechanisms at the tissue level.

Citing Articles

Evaluation of finite element modeling methods for predicting compression screw failure in a custom pelvic implant.

Zhu Y, Babazadeh-Naseri A, Brake M, Akin J, Li G, Lewis V Front Bioeng Biotechnol. 2024; 12:1420870.

PMID: 39234264 PMC: 11372789. DOI: 10.3389/fbioe.2024.1420870.


3D-Printed PEEK/Silicon Nitride Scaffolds with a Triply Periodic Minimal Surface Structure for Spinal Fusion Implants.

Du X, Ronayne S, Lee S, Hendry J, Hoxworth D, Bock R ACS Appl Bio Mater. 2023; 6(8):3319-3329.

PMID: 37561906 PMC: 10445264. DOI: 10.1021/acsabm.3c00383.


Prospect of Metal Ceramic (Titanium-Wollastonite) Composite as Permanent Bone Implants: A Narrative Review.

Shanmuganantha L, Baharudin A, Sulong A, Shamsudin R, Ng M Materials (Basel). 2021; 14(2).

PMID: 33430455 PMC: 7826931. DOI: 10.3390/ma14020277.


Complex biomechanical properties of non-augmented and augmented pedicle screws in human vertebrae with reduced bone density.

Schulze M, Riesenbeck O, Vordemvenne T, Raschke M, Evers J, Hartensuer R BMC Musculoskelet Disord. 2020; 21(1):151.

PMID: 32143605 PMC: 7060638. DOI: 10.1186/s12891-020-3158-z.


Efficient materially nonlinear [Formula: see text]FE solver for simulations of trabecular bone failure.

Stipsitz M, Zysset P, Pahr D Biomech Model Mechanobiol. 2019; 19(3):861-874.

PMID: 31749070 PMC: 7203600. DOI: 10.1007/s10237-019-01254-x.


References
1.
Goldstein S . The mechanical properties of trabecular bone: dependence on anatomic location and function. J Biomech. 1987; 20(11-12):1055-61. DOI: 10.1016/0021-9290(87)90023-6. View

2.
Mitton D, Rumelhart C, Hans D, Meunier P . The effects of density and test conditions on measured compression and shear strength of cancellous bone from the lumbar vertebrae of ewes. Med Eng Phys. 1997; 19(5):464-74. DOI: 10.1016/s1350-4533(97)00001-5. View

3.
Morgan E, Keaveny T . Dependence of yield strain of human trabecular bone on anatomic site. J Biomech. 2001; 34(5):569-77. DOI: 10.1016/s0021-9290(01)00011-2. View

4.
Keller T . Predicting the compressive mechanical behavior of bone. J Biomech. 1994; 27(9):1159-68. DOI: 10.1016/0021-9290(94)90056-6. View

5.
Verhulp E, van Rietbergen B, Muller R, Huiskes R . Indirect determination of trabecular bone effective tissue failure properties using micro-finite element simulations. J Biomech. 2008; 41(7):1479-85. DOI: 10.1016/j.jbiomech.2008.02.032. View