» Articles » PMID: 26780714

Fixation of a Split Fracture of the Lateral Tibial Plateau with a Locking Screw Plate Instead of Cannulated Screws Would Allow Early Weight Bearing: a Computational Exploration

Overview
Journal Int Orthop
Specialty Orthopedics
Date 2016 Jan 19
PMID 26780714
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To assess, with finite element (FE) calculations, whether immediate weight bearing would be possible after surgical stabilization either with cannulated screws or with a locking plate in a split fracture of the lateral tibial plateau (LTP).

Methods: A split fracture of the LTP was recreated in a FE model of a human tibia. A three-dimensional FE model geometry of a human femur-tibia system was obtained from the VAKHUM project database, and was built from CT images from a subject with normal bone morphologies and normal alignment. The mesh of the tibia was reconverted into a geometry of NURBS surfaces. A split fracture of the lateral tibial plateau was reproduced by using geometrical data from patient radiographs. A locking screw plate (LP) and a cannulated screw (CS) systems were modelled to virtually reduce the fracture and 80 kg static body-weight was simulated.

Results: While the simulated body-weight led to clinically acceptable interfragmentary motion, possible traumatic bone shear stresses were predicted nearby the cannulated screws. With a maximum estimation of about 1.7 MPa maximum bone shear stresses, the Polyax system might ensure more reasonable safety margins.

Conclusions: Split fractures of the LTP fixed either with locking screw plate or cannulated screws showed no clinically relevant IFM in a FE model. The locking screw plate showed higher mechanical stability than cannulated screw fixation. The locking screw plate might also allow full or at least partial weight bearing under static posture at time zero.

Citing Articles

Immediate weight-bearing after tibial plateau fractures internal fixation results in better clinical outcomes with similar radiological outcomes: a randomized clinical trial.

Ibrahim M, Moustafa M, Brismee J, Farouk O, Abdelnasser M, Said H Int Orthop. 2025; .

PMID: 39964437 DOI: 10.1007/s00264-025-06443-1.


Higher interfragmentary compression force improves lateral tibial plateau fracture stability using locking plate fixation: experimental and simulation verification.

Xu D, Jiang J, Ji Z, Wang F, Jia R, Hong H BMC Musculoskelet Disord. 2024; 25(1):1084.

PMID: 39736560 PMC: 11684052. DOI: 10.1186/s12891-024-08214-2.


Application of a combined cancellous lag screw enhances the stability of locking plate fixation of osteoporotic lateral tibial plateau fracture by providing interfragmentary compression force.

Jiang J, Xu D, Ji Z, Wang F, Jia R, Wang J J Orthop Surg Res. 2024; 19(1):139.

PMID: 38351078 PMC: 10865576. DOI: 10.1186/s13018-024-04564-8.


Suprapatellar intramedullary nail combined with screw fixation has comparable surgical outcomes to minimally invasive locking plate fixation in ipsilateral tibial plateau and shaft fractures.

Lim S, Song H, Kim T, Park D, Lee J, Chung J Arch Orthop Trauma Surg. 2023; 144(2):673-681.

PMID: 38032381 DOI: 10.1007/s00402-023-05147-8.


Biomechanical study of a new rim plate fixation strategy for two kinds of posterolateral depression patterns of tibial plateau fractures: a finite element analysis.

Zhang B, Wang B, Mei J, Luo C, Zhu Y J Orthop Surg Res. 2023; 18(1):840.

PMID: 37932801 PMC: 10629018. DOI: 10.1186/s13018-023-04315-1.


References
1.
Ratcliff J, Werner F, Green J, Harley B . Medial buttress versus lateral locked plating in a cadaver medial tibial plateau fracture model. J Orthop Trauma. 2007; 21(7):444-8. DOI: 10.1097/BOT.0b013e318126bb73. View

2.
Karunakar M, Egol K, Peindl R, Harrow M, Bosse M, Kellam J . Split depression tibial plateau fractures: a biomechanical study. J Orthop Trauma. 2002; 16(3):172-7. DOI: 10.1097/00005131-200203000-00006. View

3.
Wang H, Chen T, Torzilli P, Warren R, Maher S . Dynamic contact stress patterns on the tibial plateaus during simulated gait: a novel application of normalized cross correlation. J Biomech. 2013; 47(2):568-74. PMC: 3936672. DOI: 10.1016/j.jbiomech.2013.11.042. View

4.
Honkonen S . Degenerative arthritis after tibial plateau fractures. J Orthop Trauma. 1995; 9(4):273-7. DOI: 10.1097/00005131-199509040-00001. View

5.
van den Munckhof S, Zadpoor A . How accurately can we predict the fracture load of the proximal femur using finite element models?. Clin Biomech (Bristol). 2014; 29(4):373-80. DOI: 10.1016/j.clinbiomech.2013.12.018. View