» Articles » PMID: 22763058

Adverse Events of Open A1 Pulley Release for Idiopathic Trigger Finger

Overview
Journal J Hand Surg Am
Publisher Elsevier
Date 2012 Jul 6
PMID 22763058
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To classify and report adverse events of trigger finger release in a large cohort of patients.

Methods: We retrospectively reviewed 1,598 trigger finger releases performed by 12 surgeons in 984 patients between 2001 and 2011. Adverse events were classified based on a system derived from the Centers for Disease Control and Prevention criteria and clinical experience. Risk factors for various adverse events were sought in bivariate and multivariable statistical analysis.

Results: At the latest follow-up, 66 patients (7%), or 84 operated trigger digits (5%), experienced a documented adverse event. The most common adverse events were recovery issues in 46 patients (3%) (such as postoperative symptoms treated with steroid injection or slow recovery of motion treated with hand therapy), wound problems in 30 patients (2%) (consisting of suture abscess, superficial infection, or wound separation), persistent postoperative triggering in 10 patients (0.6%), and recurrent triggering in 4 patients (0.3%). Diabetes mellitus was associated with wound problems, slow recovery of motion, and recurrence. Concomitant carpal tunnel release on the same side was associated with slow recovery.

Conclusions: Fourteen patients, less than 1%, in this cohort experienced an adverse event, such as persistent or recurrent triggering, requiring secondary surgery. No nerve injury or deep infection occurred in our cohort. One in 15 patients experienced a minor transient or treatable adverse event, and patients with diabetes were at greater risk.

Type Of Study/level Of Evidence: Therapeutic IV.

Citing Articles

A1 pulley cutting potential and safety of three ultrasound-guided percutaneous A1 pulley release techniques for trigger finger: a cadaveric study.

de la Fuente J, Blasi M, Davila F, Ribera A, Sala-Blanch X, Balius R J Orthop Surg Res. 2025; 20(1):215.

PMID: 40016848 PMC: 11869403. DOI: 10.1186/s13018-025-05590-w.


Factors affecting prognosis in open A1 pulley release surgery for trigger finger.

Bezirgan U, Bekar H, Savran M, Yogun Y, Armangil M Jt Dis Relat Surg. 2024; 36(1):78-84.

PMID: 39719904 PMC: 11734839. DOI: 10.52312/jdrs.2024.1885.


Comparison of efficacy and safety of USG-guided versus blind pulley release for trigger finger: A systematic review and meta-analysis.

Rohilla R, Kaur H, Tiwari P J Clin Orthop Trauma. 2024; 58:102795.

PMID: 39554281 PMC: 11566334. DOI: 10.1016/j.jcot.2024.102795.


Local ketorolac infiltration for postoperative pain in open trigger finger surgery: a randomized controlled trial.

Auwattanamongkol T, Laohaprasitiporn P, Monteerarat Y, Limthongthang R, Vathana T BMC Musculoskelet Disord. 2024; 25(1):746.

PMID: 39289657 PMC: 11406808. DOI: 10.1186/s12891-024-07856-6.


Percutaneous Surgical Treatment of Trigger Finger.

Orhan S Rev Bras Ortop (Sao Paulo). 2024; 59(4):e580-e583.

PMID: 39239583 PMC: 11374397. DOI: 10.1055/s-0044-1788670.