A Pre-clinical Test Platform for the Functional Evaluation of Scaffolds for Musculoskeletal Defects: the Meniscus

Overview
Journal HSS J
Date 2012 Jul 4
PMID 22754417
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

In an attempt to delay the progression of osteoarthritis from an index injury, early intervention via repair of injured musculoskeletal soft tissue has been advocated. Despite the development of a number of scaffolds intended to treat soft tissue defects, information about their functional performance is lacking. The goal of this study was to consolidate a suite of in vitro and in vivo models into a pre-clinical test platform to assess the functional performance of meniscal repair scaffolds. Our objective was to assess the ability of a scaffold (Actifit™; Orteq, UK) to carry load without detrimentally abrading against articular cartilage. Three test modules were used to assess the functional performance of meniscal repair scaffolds. The first module tested the ability of the scaffold to carry load in an in vitro model designed to measure the change in normal contact stress magnitude on the tibial plateau of cadaveric knees after scaffold implantation. The second module assessed the in vitro frictional coefficient of the scaffold against cartilage to assess the likelihood that the scaffold would destructively abrade against articular cartilage in vivo. The third module consisted of an assessment of functional performance in vivo by measuring the structure and composition of articular cartilage across the tibial plateau 12 months after scaffold implantation in an ovine model. In vitro, the scaffold improved contact mechanics relative to a partly meniscectomized knee suggesting that, in vivo, less damage would be seen in the scaffold implanted knees vs. partly meniscectomized knees. However, there was no significant difference in the condition of articular cartilage between the two groups. Moreover, in spite of the high coefficient of friction between the scaffold and articular cartilage, there was no significant damage in the articular cartilage underneath the scaffold. The discrepancy between the in vitro and in vivo models was likely influenced by the abundant tissue generated within the scaffold and the unexpected tissue that regenerated within the site of the partial meniscectomy. We are currently augmenting our suite of tests so that we can pre-clinically evaluate the functional performance at time zero and as a function of time after implantation.

Citing Articles

An ovine knee simulator: description and proof of concept.

Bartolo M, Newman S, Dandridge O, Halewood C, Accardi M, Dini D Front Bioeng Biotechnol. 2024; 12:1410053.

PMID: 38994124 PMC: 11237960. DOI: 10.3389/fbioe.2024.1410053.


Synthetic PVA Osteochondral Implants for the Knee Joint: Mechanical Characteristics During Simulated Gait.

Chen T, Brial C, McCarthy M, Warren R, Maher S Am J Sports Med. 2021; 49(11):2933-2941.

PMID: 34347534 PMC: 9092221. DOI: 10.1177/03635465211028566.


Meniscal repair: The current state and recent advances in augmentation.

Bansal S, Floyd E, Kowalski M, Aikman E, Elrod P, Burkey K J Orthop Res. 2021; 39(7):1368-1382.

PMID: 33751642 PMC: 8249336. DOI: 10.1002/jor.25021.


Articular cartilage and meniscus reveal higher friction in swing phase than in stance phase under dynamic gait conditions.

Warnecke D, Messemer M, de Roy L, Stein S, Gentilini C, Walker R Sci Rep. 2019; 9(1):5785.

PMID: 30962482 PMC: 6453962. DOI: 10.1038/s41598-019-42254-2.


A Wearable Magnet-Based System to Assess Activity and Joint Flexion in Humans and Large Animals.

Qu F, Stoeckl B, Gebhard P, Hullfish T, Baxter J, Mauck R Ann Biomed Eng. 2018; 46(12):2069-2078.

PMID: 30083860 PMC: 6249046. DOI: 10.1007/s10439-018-2105-8.


References
1.
Maher S, Rodeo S, Doty S, Brophy R, Potter H, Foo L . Evaluation of a porous polyurethane scaffold in a partial meniscal defect ovine model. Arthroscopy. 2010; 26(11):1510-9. DOI: 10.1016/j.arthro.2010.02.033. View

2.
Kon E, Chiari C, Marcacci M, Delcogliano M, Salter D, Martin I . Tissue engineering for total meniscal substitution: animal study in sheep model. Tissue Eng Part A. 2008; 14(6):1067-80. DOI: 10.1089/ten.tea.2007.0193. View

3.
Chiari C, Koller U, Dorotka R, Eder C, Plasenzotti R, Lang S . A tissue engineering approach to meniscus regeneration in a sheep model. Osteoarthritis Cartilage. 2006; 14(10):1056-65. DOI: 10.1016/j.joca.2006.04.007. View

4.
Becker R, Wirz D, Wolf C, Gopfert B, Nebelung W, Friederich N . Measurement of meniscofemoral contact pressure after repair of bucket-handle tears with biodegradable implants. Arch Orthop Trauma Surg. 2004; 125(4):254-60. DOI: 10.1007/s00402-004-0739-5. View

5.
Haut Donahue T, Hull M, Rashid M, Jacobs C . How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint. J Biomech. 2002; 36(1):19-34. DOI: 10.1016/s0021-9290(02)00305-6. View