» Articles » PMID: 22634080

Internal Calibrants Allow High Accuracy Peptide Matching Between MALDI Imaging MS and LC-MS/MS

Overview
Journal J Proteomics
Publisher Elsevier
Specialty Biochemistry
Date 2012 May 29
PMID 22634080
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

One of the important challenges for MALDI imaging mass spectrometry (MALDI-IMS) is the unambiguous identification of measured analytes. One way to do this is to match tryptic peptide MALDI-IMS m/z values with LC-MS/MS identified m/z values. Matching using current MALDI-TOF/TOF MS instruments is difficult due to the variability of in situ time-of-flight (TOF) m/z measurements. This variability is currently addressed using external calibration, which limits achievable mass accuracy for MALDI-IMS and makes it difficult to match these data to downstream LC-MS/MS results. To overcome this challenge, the work presented here details a method for internally calibrating data sets generated from tryptic peptide MALDI-IMS on formalin-fixed paraffin-embedded sections of ovarian cancer. By calibrating all spectra to internal peak features the m/z error for matches made between MALDI-IMS m/z values and LC-MS/MS identified peptide m/z values was significantly reduced. This improvement was confirmed by follow up matching of LC-MS/MS spectra to in situ MS/MS spectra from the same m/z peak features. The sum of the data presented here indicates that internal calibrants should be a standard component of tryptic peptide MALDI-IMS experiments.

Citing Articles

Use of tryptic peptide MALDI mass spectrometry imaging to identify the spatial proteomic landscape of colorectal cancer liver metastases.

Li C, Briggs M, Lee Y, Tin T, Young C, Pierides J Clin Exp Med. 2024; 24(1):53.

PMID: 38492056 PMC: 10944452. DOI: 10.1007/s10238-024-01311-5.


Emerging Computational Methods in Mass Spectrometry Imaging.

Hu H, Laskin J Adv Sci (Weinh). 2022; 9(34):e2203339.

PMID: 36253139 PMC: 9731724. DOI: 10.1002/advs.202203339.


A Protocol for the Acquisition of Comprehensive Proteomics Data from Single Cases Using Formalin-Fixed Paraffin Embedded Sections.

Acland M, Mittal P, Arentz G, Whitehead F, Hoffmann P, Klingler-Hoffmann M Methods Protoc. 2022; 5(4).

PMID: 35893583 PMC: 9326557. DOI: 10.3390/mps5040057.


Moving translational mass spectrometry imaging towards transparent and reproducible data analyses: a case study of an urothelial cancer cohort analyzed in the Galaxy framework.

Foll M, Volkmann V, Enderle-Ammour K, Timme S, Wilhelm K, Guo D Clin Proteomics. 2022; 19(1):8.

PMID: 35439943 PMC: 9016955. DOI: 10.1186/s12014-022-09347-z.


A simple preparation protocol for shipping and storage of tissue sections for laser ablation-inductively coupled plasma-mass spectrometry imaging.

Buchholz R, Krossa S, Andersen M, Holtkamp M, Sperling M, Karst U Metallomics. 2022; 14(3).