Impact of Changes of Positive End-expiratory Pressure on Functional Residual Capacity at Low Tidal Volume Ventilation During General Anesthesia

Overview
Journal J Anesth
Specialty Anesthesiology
Date 2012 May 16
PMID 22584817
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Several reports in the literature have described the effects of positive end-expiratory pressure (PEEP) level upon functional residual capacity (FRC) in ventilated patients during general anesthesia. This study compares FRC in mechanically low tidal volume ventilation with different PEEP levels during upper abdominal surgery.

Methods: Before induction of anesthesia (awake) for nine patients with upper abdominal surgery, a tight-seal facemask was applied with 2 cmH(2)O pressure support ventilation and 100 % O(2) during FRC measurements conducted on patients in a supine position. After tracheal intubation, lungs were ventilated with bilevel airway pressure with a volume guarantee (7 ml/kg predicted body weight) and with an inspired oxygen fraction (FIO(2)) of 0.4. PEEP levels of 0, 5, and 10 cmH(2)O were used. Each level of 5 and 10 cmH(2)O PEEP was maintained for 2 h. FRC was measured at each PEEP level.

Results: FRC awake was significantly higher than that at PEEP 0 cmH(2)O (P < 0.01). FRC at PEEP 0 cmH(2)O was significantly lower than that at 10 cmH(2)O (P < 0.01). PaO(2)/FIO(2) awake was significantly higher than that for PEEP 0 cmH(2)O (P < 0.01). PaO(2)/FIO(2) at PEEP 0 cmH(2)O was significantly lower than that for PEEP 5 cmH(2)O or PEEP 10 cmH(2)O (P < 0.01). Furthermore, PEEP 0 cmH(2)O, PEEP 5 cmH(2)O after 2 h, and PEEP 10 cmH(2)O after 2 h were correlated with FRC (R = 0.671, P < 0.01) and PaO(2)/FIO(2) (R = 0.642, P < 0.01).

Conclusions: Results suggest that PEEP at 10 cmH(2)O is necessary to maintain lung function if low tidal volume ventilation is used during upper abdominal surgery.

Citing Articles

Our Experience of Managing Central Airway Tumors: Anesthesia Perspectives.

Madathil T, Poduval D, Jose T, Panidapu N, Jose D, Joseph T Ann Card Anaesth. 2025; 28(1):3-9.

PMID: 39851145 PMC: 11902365. DOI: 10.4103/aca.aca_118_24.


Design and Implementation of a Computer-Controlled Hybrid Oscillatory Ventilator.

Cruz A, Herrmann J, Hajdarevic B, Hawley M, Fox D, Bates J J Med Device. 2024; 19(1):011001.

PMID: 39464246 PMC: 11500807. DOI: 10.1115/1.4066679.


Lung-protective mechanical ventilation for patients undergoing abdominal laparoscopic surgeries: a randomized controlled trial.

Nguyen T, Nguyen V, Nguyen T, Mai D, Nguyen N, Vu T BMC Anesthesiol. 2021; 21(1):95.

PMID: 33784987 PMC: 8008676. DOI: 10.1186/s12871-021-01318-5.


Effect of individualized PEEP titration guided by intratidal compliance profile analysis on regional ventilation assessed by electrical impedance tomography - a randomized controlled trial.

Weber J, Gutjahr J, Schmidt J, Lozano-Zahonero S, Borgmann S, Schumann S BMC Anesthesiol. 2020; 20(1):42.

PMID: 32079526 PMC: 7033933. DOI: 10.1186/s12871-020-00960-9.


Positive end-expiratory pressure increases arterial oxygenation in elderly patients undergoing urological surgery using laryngeal mask airway in lithotomy position.

Kim D, Park J, Yu J, Koh G, Kim E, Hwang J J Clin Monit Comput. 2019; 34(1):161-169.

PMID: 30788809 DOI: 10.1007/s10877-019-00281-4.


References
1.
Hewlett A, Hulands G, NUNN J, Milledge J . Functional residual capacity during anaesthesia III: Artificial ventilation. Br J Anaesth. 1974; 46(7):495-503. DOI: 10.1093/bja/46.7.495. View

2.
Maisch S, Reissmann H, Fuellekrug B, Weismann D, Rutkowski T, Tusman G . Compliance and dead space fraction indicate an optimal level of positive end-expiratory pressure after recruitment in anesthetized patients. Anesth Analg. 2008; 106(1):175-81, table of contents. DOI: 10.1213/01.ane.0000287684.74505.49. View

3.
Neumann P, Zinserling J, Haase C, Sydow M, Burchardi H . Evaluation of respiratory inductive plethysmography in controlled ventilation: measurement of tidal volume and PEEP-induced changes of end-expiratory lung volume. Chest. 1998; 113(2):443-51. DOI: 10.1378/chest.113.2.443. View

4.
Pelosi P, Ravagnan I, Giurati G, Panigada M, Bottino N, Tredici S . Positive end-expiratory pressure improves respiratory function in obese but not in normal subjects during anesthesia and paralysis. Anesthesiology. 1999; 91(5):1221-31. DOI: 10.1097/00000542-199911000-00011. View

5.
Wahba R . Perioperative functional residual capacity. Can J Anaesth. 1991; 38(3):384-400. DOI: 10.1007/BF03007630. View