An Acoustic Glucose Sensor
Overview
Biotechnology
Affiliations
In vivo glucose monitoring is required for tighter glycaemic control. This report describes a new approach to construct a miniature implantable device based on a magnetic acoustic resonance sensor (MARS). A ≈ 600-800 nm thick glucose-responsive poly(acrylamide-co-3-acrylamidophenylboronic acid) (poly(acrylamide-co-3-APB)) film was polymerised on the quartz disc (12 mm in diameter and 0.25 mm thick) of the MARS. The swelling/shrinking of the polymer film induced by the glucose binding to the phenylboronate caused changes in the resonance amplitude of the quartz disc in the MARS. A linear relationship between the response of the MARS and the glucose concentration in the range ≈ 0-15 mM was observed, with the optimum response of the MARS sensor being obtained when the polymer films contained ≈ 20 mol% 3-APB. The MARS glucose sensor also functioned under flow conditions (9 μl/min) with a response almost identical to the sensor under static or non-flow conditions. The results suggest that the MARS could offer a promising strategy for developing a small subcutaneously implanted continuous glucose monitor.
Biosensors with Boronic Acid-Based Materials as the Recognition Elements and Signal Labels.
Liu L, Ma X, Chang Y, Guo H, Wang W Biosensors (Basel). 2023; 13(8).
PMID: 37622871 PMC: 10452607. DOI: 10.3390/bios13080785.
Zhang M, Yang X, Ren M, Mao S, Dhakal R, Kim N Sci Rep. 2022; 12(1):15961.
PMID: 36153402 PMC: 9509396. DOI: 10.1038/s41598-022-20285-6.
Xu J, Sun Y, Zhang J Sci Rep. 2020; 10(1):16026.
PMID: 32994458 PMC: 7524729. DOI: 10.1038/s41598-020-73090-4.
Li Y, Yao Z, Yue W, Zhang C, Gao S, Wang C Sensors (Basel). 2020; 20(6).
PMID: 32168963 PMC: 7146331. DOI: 10.3390/s20061565.
Li H, Zhang L, Mao Y, Wen C, Zhao P Nanoscale Res Lett. 2019; 14(1):135.
PMID: 30997590 PMC: 6470241. DOI: 10.1186/s11671-019-2966-2.