» Articles » PMID: 22311085

Progress Toward Multiplexed Sample-to-result Detection in Low Resource Settings Using Microfluidic Immunoassay Cards

Overview
Journal Lab Chip
Specialties Biotechnology
Chemistry
Date 2012 Feb 8
PMID 22311085
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

In many low resource settings multiple diseases are endemic. There is a need for appropriate multi-analyte diagnostics capable of differentiating between diseases that cause similar clinical symptoms. The work presented here was part of a larger effort to develop a microfluidic point-of-care system, the DxBox, for sample-to-result differential diagnosis of infections that present with high rapid-onset fever. Here we describe a platform that detects disease-specific antigens and IgM antibodies. The disposable microfluidic cards are based on a flow-through membrane immunoassay carried out on porous nitrocellulose, which provides rapid diffusion for short assay times and a high surface area for visual detection of colored assay spots. Fluid motion and on-card valves were driven by a pneumatic system and we present designs for using pneumatic control to carry out assay functions. Pneumatic actuation, while having the potential advantage of inexpensive and robust hardware, introduced bubbles that interfered with fluidic control and affected assay results. The cards performed all sample preparation steps including plasma filtration from whole blood, sample and reagent aliquoting for the two parallel assays, sample dilution, and IgG removal for the IgM assays. We demonstrated the system for detection of the malarial pfHRPII antigen (spiked) and IgM antibodies to Salmonella Typhi LPS (patient plasma samples). All reagents were stored on card in dry form; only the sample and buffer were required to run the tests. Here we detail the development of this platform and discuss its strengths and weaknesses.

Citing Articles

Potential Microfluidic Devices for COVID-19 Antibody Detection at Point-of-Care (POC): A Review.

Tayyab M, Sami M, Raji H, Mushnoori S, Javanmard M IEEE Sens J. 2023; 21(4):4007-4017.

PMID: 37974932 PMC: 8768978. DOI: 10.1109/JSEN.2020.3034892.


Taguchi method: artificial neural network approach for the optimization of high-efficiency microfluidic biosensor for COVID-19.

Ben Romdhane I, Jemmali A, Kaziz S, Echouchene F, AlShahrani T, Belmabrouk H Eur Phys J Plus. 2023; 138(4):359.

PMID: 37131342 PMC: 10132959. DOI: 10.1140/epjp/s13360-023-03988-1.


Translating diagnostics and drug delivery technologies to low-resource settings.

Euliano E, Sklavounos A, Wheeler A, McHugh K Sci Transl Med. 2022; 14(666):eabm1732.

PMID: 36223447 PMC: 9716722. DOI: 10.1126/scitranslmed.abm1732.


Rotary manifold for automating a paper-based immunoassay.

Carrell C, Wydallis R, Bontha M, Boehle K, Beveridge J, Geiss B RSC Adv. 2022; 9(50):29078-29086.

PMID: 35528425 PMC: 9071810. DOI: 10.1039/c9ra07106g.


Multi-Omics Advancements towards Malaria Diagnosis.

Aggarwal S, Peng W, Srivastava S Diagnostics (Basel). 2021; 11(12).

PMID: 34943459 PMC: 8700291. DOI: 10.3390/diagnostics11122222.