Abstract

An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L(-1) (r(2) = 0.993), with a detection limit of 0.81 mg L(-1) (S/N = 3). The proposed system showed good precision, with relative standard deviations (RSDs) of 5.1%, when evaluated with 10 mg L(-1) albumin (n = 10). Determination of urinary albumin with the proposed system gave results highly similar to those determined by the conventional spectrophotometric method using immunoturbidimetric detection (r(2) = 0.995; n = 15).

Citing Articles

Colorimetric Detection Based on Localized Surface Plasmon Resonance for Determination of Chemicals in Urine.

Lertvachirapaiboon C, Baba A, Shinbo K, Kato K Anal Sci. 2020; 37(7):929-940.

PMID: 33132235 DOI: 10.2116/analsci.20R005.


A Low-Cost Micro-Volume Nephelometric System for Quantitative Immunoagglutination Assays.

Sun Q, Zheng W, Lin C, Shen D Sensors (Basel). 2019; 19(20).

PMID: 31600932 PMC: 6832725. DOI: 10.3390/s19204359.


A highly efficient bead extraction technique with low bead number for digital microfluidic immunoassay.

Huang C, Tsai P, Lee I, Hsu H, Huang H, Fan S Biomicrofluidics. 2016; 10(1):011901.

PMID: 26858807 PMC: 4714987. DOI: 10.1063/1.4939942.


Microfluidic opportunities in the field of nutrition.

Li S, Kiehne J, Sinoway L, Cameron C, Huang T Lab Chip. 2013; 13(20):3993-4003.

PMID: 24056522 PMC: 3875330. DOI: 10.1039/c3lc90090h.


Albumin testing in urine using a smart-phone.

Coskun A, Nagi R, Sadeghi K, Phillips S, Ozcan A Lab Chip. 2013; 13(21):4231-8.

PMID: 23995895 PMC: 3810448. DOI: 10.1039/c3lc50785h.


References
1.
Songjaroen T, Maturos T, Sappat A, Tuantranont A, Laiwattanapaisal W . Portable microfluidic system for determination of urinary creatinine. Anal Chim Acta. 2009; 647(1):78-83. DOI: 10.1016/j.aca.2009.05.014. View

2.
Panini N, Messina G, Salinas E, Fernandez H, Raba J . Integrated microfluidic systems with an immunosensor modified with carbon nanotubes for detection of prostate specific antigen (PSA) in human serum samples. Biosens Bioelectron. 2007; 23(7):1145-51. DOI: 10.1016/j.bios.2007.11.003. View

3.
Degre G, Brunet E, Dodge A, Tabeling P . Improving agglutination tests by working in microfluidic channels. Lab Chip. 2005; 5(6):691-4. DOI: 10.1039/b501695a. View

4.
Gross J, de Azevedo M, Silveiro S, Canani L, Caramori M, Zelmanovitz T . Diabetic nephropathy: diagnosis, prevention, and treatment. Diabetes Care. 2004; 28(1):164-76. DOI: 10.2337/diacare.28.1.164. View

5.
Bland J, Altman D . Measuring agreement in method comparison studies. Stat Methods Med Res. 1999; 8(2):135-60. DOI: 10.1177/096228029900800204. View