» Articles » PMID: 22167429

Effect of Implant Abutment Modification on the Extrusion of Excess Cement at the Crown-abutment Margin for Cement-retained Implant Restorations

Overview
Specialty Dentistry
Date 2011 Dec 15
PMID 22167429
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To compare the effect of implant abutment modification on the amount of cement extruded at the crown-abutment margin and to evaluate the vertical discrepancy after cementation.

Materials And Methods: Access openings of titanium abutments were modified with an opening (open) and placement of two vent holes 3 mm from the occlusal edge and 180 degrees apart (internal vent). Access openings were filled with resin material (closed) and used as controls. Each abutment was secured to an implant analog. Eugenol-free zinc oxide cement (TempBond NE) was selected to cement the cast crowns (n = 9) onto test abutments. The amount of cement extruded out of the margin was calculated, and vertical seating discrepancies were determined with a linear transducer device before and after cementation. Differences among groups were analyzed statistically.

Results: The mean amount of extruded cement ranged from 36% to 90% of the total cement placed within the crowns. The order, from least to greatest amount of excess cement extrusion at the margins, was internal vent, open, and closed; significant differences were observed between test groups. The net vertical discrepancies of tested specimens ranged from -7 μm to +6 μm (mean, 0 μm). No statistically significant differences in vertical discrepancy were found between the groups.

Conclusions: Venting the hollow abutment resulted in the least amount of cement extrusion when compared to closing off the screw access channel or leaving it open. Within the limitations of this study, it may be concluded that the use of two, 0.75-mm radius vent holes placed 3 mm apical to the occlusal area of the abutment and 180 degrees apart will limit the amount of cement extruded into the gingival sulcus of implant-retained crowns.

Citing Articles

A Comparative Evaluation of Vertical Marginal Gap for Vented and Precemented Cad-Cam Zirconium Copings on Angulated Abutments: An Study.

Passanha D, Sankeshwari B, Pattanshetti C, Dhole R, Miyyapuram S, Zawar Y J Pharm Bioallied Sci. 2023; 15(Suppl 2):S934-S936.

PMID: 37693993 PMC: 10485502. DOI: 10.4103/jpbs.jpbs_283_23.


Selection of 1-mm venting or 2.5-mm screw access holes on implant crowns based on cement extrusion and retention capacity.

Zhou H, Ye S, Liu M, Feng H, Wen C BMC Oral Health. 2022; 22(1):108.

PMID: 35366875 PMC: 8976311. DOI: 10.1186/s12903-022-02145-x.


A Systematic Review of Cementation Techniques to Minimize Cement Excess in Cement-Retained Implant Restorations.

Reda R, Zanza A, Cicconetti A, Bhandi S, Guarnieri R, Testarelli L Methods Protoc. 2022; 5(1).

PMID: 35076562 PMC: 8788496. DOI: 10.3390/mps5010009.


One-Abutment One-Time Effect on Peri-Implant Marginal Bone: A Prospective, Controlled, Randomized, Double-Blind Study.

Moreira F, Rocha S, Caramelo F, Tondela J Materials (Basel). 2021; 14(15).

PMID: 34361372 PMC: 8348384. DOI: 10.3390/ma14154179.


A finite element analysis of novel vented dental abutment geometries for cement-retained crown restorations.

Rodriguez L, Saba J, Meyer C, Chung K, Wadhwani C, Rodrigues D Clin Exp Dent Res. 2018; 2(2):136-145.

PMID: 29744160 PMC: 5839249. DOI: 10.1002/cre2.33.