» Articles » PMID: 22157812

Synthetic, Multi-layer, Self-oscillating Vocal Fold Model Fabrication

Overview
Journal J Vis Exp
Date 2011 Dec 14
PMID 22157812
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Sound for the human voice is produced via flow-induced vocal fold vibration. The vocal folds consist of several layers of tissue, each with differing material properties. Normal voice production relies on healthy tissue and vocal folds, and occurs as a result of complex coupling between aerodynamic, structural dynamic, and acoustic physical phenomena. Voice disorders affect up to 7.5 million annually in the United States alone and often result in significant financial, social, and other quality-of-life difficulties. Understanding the physics of voice production has the potential to significantly benefit voice care, including clinical prevention, diagnosis, and treatment of voice disorders. Existing methods for studying voice production include in vivo experimentation using human and animal subjects, in vitro experimentation using excised larynges and synthetic models, and computational modeling. Owing to hazardous and difficult instrument access, in vivo experiments are severely limited in scope. Excised larynx experiments have the benefit of anatomical and some physiological realism, but parametric studies involving geometric and material property variables are limited. Further, they are typically only able to be vibrated for relatively short periods of time (typically on the order of minutes). Overcoming some of the limitations of excised larynx experiments, synthetic vocal fold models are emerging as a complementary tool for studying voice production. Synthetic models can be fabricated with systematic changes to geometry and material properties, allowing for the study of healthy and unhealthy human phonatory aerodynamics, structural dynamics, and acoustics. For example, they have been used to study left-right vocal fold asymmetry, clinical instrument development, laryngeal aerodynamics, vocal fold contact pressure, and subglottal acoustics (a more comprehensive list can be found in Kniesburges et al.) Existing synthetic vocal fold models, however, have either been homogenous (one-layer models) or have been fabricated using two materials of differing stiffness (two-layer models). This approach does not allow for representation of the actual multi-layer structure of the human vocal folds that plays a central role in governing vocal fold flow-induced vibratory response. Consequently, one- and two-layer synthetic vocal fold models have exhibited disadvantages such as higher onset pressures than what are typical for human phonation (onset pressure is the minimum lung pressure required to initiate vibration), unnaturally large inferior-superior motion, and lack of a "mucosal wave" (a vertically-traveling wave that is characteristic of healthy human vocal fold vibration). In this paper, fabrication of a model with multiple layers of differing material properties is described. The model layers simulate the multi-layer structure of the human vocal folds, including epithelium, superficial lamina propria (SLP), intermediate and deep lamina propria (i.e., ligament; a fiber is included for anterior-posterior stiffness), and muscle (i.e., body) layers. Results are included that show that the model exhibits improved vibratory characteristics over prior one- and two-layer synthetic models, including onset pressure closer to human onset pressure, reduced inferior-superior motion, and evidence of a mucosal wave.

Citing Articles

Comparison of Aerodynamic and Elastic Properties in Tissue and Synthetic Models of Vocal Fold Vibrations.

Michaud-Dorko J, de Luzan C, Dion G, Gutmark E, Oren L Bioengineering (Basel). 2024; 11(8).

PMID: 39199792 PMC: 11351855. DOI: 10.3390/bioengineering11080834.


Synthetic, self-oscillating vocal fold models for voice production researcha).

Thomson S J Acoust Soc Am. 2024; 156(2):1283-1308.

PMID: 39172710 PMC: 11348498. DOI: 10.1121/10.0028267.


Three-Dimensional Printing of Ultrasoft Silicone with a Functional Stiffness Gradient.

Young C, OBannon M, Thomson S 3D Print Addit Manuf. 2024; 11(2):435-445.

PMID: 38689918 PMC: 11057526. DOI: 10.1089/3dp.2022.0218.


Flow-induced oscillations of vocal-fold replicas with tuned extensibility and material properties.

Luizard P, Bailly L, Yousefi-Mashouf H, Girault R, Orgeas L, Henrich Bernardoni N Sci Rep. 2023; 13(1):22658.

PMID: 38114547 PMC: 10730560. DOI: 10.1038/s41598-023-48080-x.


Effect of nodule size and stiffness on phonation threshold and collision pressures in a synthetic hemilaryngeal vocal fold model.

Motie-Shirazi M, Zanartu M, Peterson S, Mehta D, Hillman R, Erath B J Acoust Soc Am. 2023; 153(1):654.

PMID: 36732229 PMC: 9884154. DOI: 10.1121/10.0016997.


References
1.
Drechsel J, Thomson S . Influence of supraglottal structures on the glottal jet exiting a two-layer synthetic, self-oscillating vocal fold model. J Acoust Soc Am. 2008; 123(6):4434-45. PMC: 2680659. DOI: 10.1121/1.2897040. View

2.
Popolo P, Titze I . Qualification of a quantitative laryngeal imaging system using videostroboscopy and videokymography. Ann Otol Rhinol Laryngol. 2008; 117(6):404-12. PMC: 2538379. DOI: 10.1177/000348940811700602. View

3.
Becker S, Kniesburges S, Muller S, Delgado A, Link G, Kaltenbacher M . Flow-structure-acoustic interaction in a human voice model. J Acoust Soc Am. 2009; 125(3):1351-61. DOI: 10.1121/1.3068444. View

4.
Spencer M, Siegmund T, Mongeau L . Determination of superior surface strains and stresses, and vocal fold contact pressure in a synthetic larynx model using digital image correlation. J Acoust Soc Am. 2008; 123(2):1089-103. DOI: 10.1121/1.2821412. View

5.
Thomson S, Mongeau L, Frankel S . Aerodynamic transfer of energy to the vocal folds. J Acoust Soc Am. 2005; 118(3 Pt 1):1689-700. DOI: 10.1121/1.2000787. View