» Articles » PMID: 22150403

Changes in the Surface of Four Calcium Silicate-containing Endodontic Materials and an Epoxy Resin-based Sealer After a Solubility Test

Overview
Journal Int Endod J
Specialty Dentistry
Date 2011 Dec 14
PMID 22150403
Citations 62
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: To compare the changes in the surface structure and elemental distribution, as well as the percentage of ion release, of four calcium silicate-containing endodontic materials with a well-established epoxy resin-based sealer, submitted to a solubility test.

Methodology: Solubility of AH Plus, iRoot SP, MTA Fillapex, Sealapex and MTA-Angelus (MTA-A) was tested according to ANSI/ADA Specification 57. The deionized water used in the solubility test was submitted to atomic absorption spectrophotometry to determine and quantify Ca(2+), Na(+), K(+), Zn(2+), Ni(2+) and Pb(2+) ions release. In addition, the outer and inner surfaces of nonsubmitted and submitted samples of each material to the solubility test were analysed by means of scanning electron microscopy and energy-dispersive spectroscopy (SEM/EDX). Statistical analysis was performed by using one-way anova and Tukey's post hoc tests (α = 0.05).

Results: Solubility results, in percentage, sorted in an increasing order were -1.24 ± 0.19 (MTA-A), 0.28 ± 0.08 (AH Plus), 5.65 ± 0.80 (Sealapex), 14.89 ± 0.73 (MTA Fillapex) and 20.64 ± 1.42 (iRoot SP). AH Plus and MTA-A were statistically similar (P > 0.05), but different from the other materials (P < 0.05). High levels of Ca(2+) ion release were observed in all groups except AH Plus sealer. MTA-A also had the highest release of Na(2+) and K(+) ions. Zn(+2) ion release was observed only with AH Plus and Sealapex sealers. After the solubility test, all surfaces had morphological changes. The loss of matrix was evident and the filler particles were more distinguishable. EDX analysis displayed high levels of calcium and carbon at the surface of Sealapex, MTA Fillapex and iRoot SP.

Conclusions: AH Plus and MTA-A were in accordance with ANSI/ADA's requirements regarding solubility whilst iRoot SP, MTA Fillapex and Sealapex did not fulfil ANSI/ADA's protocols. High levels of Ca(2+) ion release were observed in all materials except AH Plus. SEM/EDX analysis revealed that all samples had morphological changes in both outer and inner surfaces after the solubility test. High levels of calcium and carbon were also observed at the surface of all materials except AH Plus and MTA-A.

Citing Articles

The effect of different bioceramic root canal sealer removal protocols on the bond strength of composite to coronal dentin in diabetic and non-diabetic patients: an ex vivo study.

Sahin Manti A, Alp C BMC Oral Health. 2025; 25(1):170.

PMID: 39891155 PMC: 11786392. DOI: 10.1186/s12903-025-05563-9.


Comparative Evaluation of pH, Calcium Ion Release, and Setting Time of Premixed and Freshly Mixed Tricalcium Silicate-based Endodontic Materials: An Study.

Soundarya N, Manoharan M, Veerabadhran M, Gawthaman M, Vinodh S, Kamatchi M Int J Clin Pediatr Dent. 2025; 17(12):1330-1334.

PMID: 39867123 PMC: 11760405. DOI: 10.5005/jp-journals-10005-3015.


Evaluation of Tissue Biocompatibility of Calcium Silicate-based and Epoxy Resin-based Sealers.

de Miranda Candeiro G, Magalhaes A, Evangelista L, Santos A, Dantas L, Paiva H Iran Endod J. 2024; 19(4):278-286.

PMID: 39469510 PMC: 11512713. DOI: 10.22037/iej.v19i4.45646.


Ex-vivo evaluation of clinically-set hydraulic sealers used with different canal dryness protocols and obturation techniques: a randomized clinical trial.

Nawar N, Elashiry M, El Banna A, Saber S, Schafer E Clin Oral Investig. 2024; 28(11):612.

PMID: 39463194 PMC: 11513728. DOI: 10.1007/s00784-024-06006-5.


Cytotoxicity and cell migration evaluation of a strontium silicate-based root canal sealer on stem cells from rat apical papilla: an in vitro study.

Zhou G, Zhao Y, Cai L, Liu L, Li X, Sun L BMC Oral Health. 2024; 24(1):1023.

PMID: 39215266 PMC: 11365132. DOI: 10.1186/s12903-024-04774-w.