» Articles » PMID: 22110702

Real-time Decoding of Brain Responses to Visuospatial Attention Using 7T FMRI

Overview
Journal PLoS One
Date 2011 Nov 24
PMID 22110702
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Brain-Computer interface technologies mean to create new communication channels between our mind and our environment, independent of the motor system, by detecting and classifying self regulation of local brain activity. BCIs can provide patients with severe paralysis a means to communicate and to live more independent lives. There has been a growing interest in using invasive recordings for BCI to improve the signal quality. This also potentially gives access to new control strategies previously inaccessible by non-invasive methods. However, before surgery, the best implantation site needs to be determined. The blood-oxygen-level dependent signal changes measured with fMRI have been shown to agree well spatially with those found with invasive electrodes, and are the best option for pre-surgical localization. We show, using real-time fMRI at 7T, that eye movement-independent visuospatial attention can be used as a reliable control strategy for BCIs. At this field strength even subtle signal changes can be detected in single trials thanks to the high contrast-to-noise ratio. A group of healthy subjects were instructed to move their attention between three (two peripheral and one central) spatial target regions while keeping their gaze fixated at the center. The activated regions were first located and thereafter the subjects were given real-time feedback based on the activity in these regions. All subjects managed to regulate local brain areas without training, which suggests that visuospatial attention is a promising new target for intracranial BCI. ECoG data recorded from one epilepsy patient showed that local changes in gamma-power can be used to separate the three classes.

Citing Articles

Closed-loop fMRI at the mesoscopic scale of columns and layers: Can we do it and why would we want to?.

Chaimow D, Lorenz R, Weiskopf N Philos Trans R Soc Lond B Biol Sci. 2024; 379(1915):20230085.

PMID: 39428874 PMC: 11513163. DOI: 10.1098/rstb.2023.0085.


Bimodal electroencephalography-functional magnetic resonance imaging dataset for inner-speech recognition.

Liwicki F, Gupta V, Saini R, De K, Abid N, Rakesh S Sci Data. 2023; 10(1):378.

PMID: 37311807 PMC: 10264396. DOI: 10.1038/s41597-023-02286-w.


Quality and denoising in real-time functional magnetic resonance imaging neurofeedback: A methods review.

Heunis S, Lamerichs R, Zinger S, Caballero-Gaudes C, Jansen J, Aldenkamp B Hum Brain Mapp. 2020; 41(12):3439-3467.

PMID: 32333624 PMC: 7375116. DOI: 10.1002/hbm.25010.


EEG-Based Brain-Computer Interfaces Using Motor-Imagery: Techniques and Challenges.

Padfield N, Zabalza J, Zhao H, Masero V, Ren J Sensors (Basel). 2019; 19(6).

PMID: 30909489 PMC: 6471241. DOI: 10.3390/s19061423.


No time for drifting: Comparing performance and applicability of signal detrending algorithms for real-time fMRI.

Kopel R, Sladky R, Laub P, Koush Y, Robineau F, Hutton C Neuroimage. 2019; 191:421-429.

PMID: 30818024 PMC: 6503944. DOI: 10.1016/j.neuroimage.2019.02.058.


References
1.
Dumoulin S, Bittar R, Kabani N, Baker Jr C, Le Goualher G, Pike G . A new anatomical landmark for reliable identification of human area V5/MT: a quantitative analysis of sulcal patterning. Cereb Cortex. 2000; 10(5):454-63. DOI: 10.1093/cercor/10.5.454. View

2.
Lopez-Gordo M, Prieto A, Pelayo F, Morillas C . Customized stimulation enhances performance of independent binary SSVEP-BCIs. Clin Neurophysiol. 2010; 122(1):128-33. DOI: 10.1016/j.clinph.2010.05.021. View

3.
Ramsey N, van de Heuvel M, Kho K, Leijten F . Towards human BCI applications based on cognitive brain systems: an investigation of neural signals recorded from the dorsolateral prefrontal cortex. IEEE Trans Neural Syst Rehabil Eng. 2006; 14(2):214-7. DOI: 10.1109/TNSRE.2006.875582. View

4.
Hochberg L, Serruya M, Friehs G, Mukand J, Saleh M, Caplan A . Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature. 2006; 442(7099):164-71. DOI: 10.1038/nature04970. View

5.
Vansteensel M, Hermes D, Aarnoutse E, Bleichner M, Schalk G, van Rijen P . Brain-computer interfacing based on cognitive control. Ann Neurol. 2010; 67(6):809-16. DOI: 10.1002/ana.21985. View