» Articles » PMID: 22101141

NeuroQuest: a Comprehensive Analysis Tool for Extracellular Neural Ensemble Recordings

Overview
Specialty Neurology
Date 2011 Nov 22
PMID 22101141
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Analyzing the massive amounts of neural data collected using microelectrodes to extract biologically relevant information is a major challenge. Many scientific findings rest on the ability to overcome these challenges and to standardize experimental analysis across labs. This can be facilitated in part through comprehensive, efficient and practical software tools disseminated to the community at large. We have developed a comprehensive, MATLAB-based software package - entitled NeuroQuest - that bundles together a number of advanced neural signal processing algorithms in a user-friendly environment. Results demonstrate the efficiency and reliability of the software compared to other software packages, and versatility over a wide range of experimental conditions.

Citing Articles

A deep convolutional visual encoding model of neuronal responses in the LGN.

Mounier E, Abdullah B, Mahdi H, Eldawlatly S Brain Inform. 2021; 8(1):11.

PMID: 34129111 PMC: 8206408. DOI: 10.1186/s40708-021-00132-6.


Converging Robotic Technologies in Targeted Neural Rehabilitation: A Review of Emerging Solutions and Challenges.

Nizamis K, Athanasiou A, Almpani S, Dimitrousis C, Astaras A Sensors (Basel). 2021; 21(6).

PMID: 33809721 PMC: 8002299. DOI: 10.3390/s21062084.


SpikeInterface, a unified framework for spike sorting.

Buccino A, Hurwitz C, Garcia S, Magland J, Siegle J, Hurwitz R Elife. 2020; 9.

PMID: 33170122 PMC: 7704107. DOI: 10.7554/eLife.61834.


MEAnalyzer - a Spike Train Analysis Tool for Multi Electrode Arrays.

Dastgheyb R, Yoo S, Haughey N Neuroinformatics. 2019; 18(1):163-179.

PMID: 31273627 DOI: 10.1007/s12021-019-09431-0.


Algorithm and software to automatically identify latency and amplitude features of local field potentials recorded in electrophysiological investigation.

Rubega M, Cecchetto C, Vassanelli S, Sparacino G Source Code Biol Med. 2017; 12:3.

PMID: 28191033 PMC: 5297145. DOI: 10.1186/s13029-017-0062-5.


References
1.
Fee M, Mitra P, Kleinfeld D . Automatic sorting of multiple unit neuronal signals in the presence of anisotropic and non-Gaussian variability. J Neurosci Methods. 1996; 69(2):175-88. DOI: 10.1016/S0165-0270(96)00050-7. View

2.
Rutishauser U, Schuman E, Mamelak A . Online detection and sorting of extracellularly recorded action potentials in human medial temporal lobe recordings, in vivo. J Neurosci Methods. 2006; 154(1-2):204-24. DOI: 10.1016/j.jneumeth.2005.12.033. View

3.
Harris K, Henze D, Csicsvari J, Hirase H, Buzsaki G . Accuracy of tetrode spike separation as determined by simultaneous intracellular and extracellular measurements. J Neurophysiol. 2000; 84(1):401-14. DOI: 10.1152/jn.2000.84.1.401. View

4.
Obeid I, Wolf P . Evaluation of spike-detection algorithms for a brain-machine interface application. IEEE Trans Biomed Eng. 2004; 51(6):905-11. DOI: 10.1109/TBME.2004.826683. View

5.
Oweiss K . A systems approach for data compression and latency reduction in cortically controlled brain machine interfaces. IEEE Trans Biomed Eng. 2006; 53(7):1364-77. DOI: 10.1109/TBME.2006.873749. View