» Articles » PMID: 22006911

Performance Benchmarks of an Array-based Hand-held Photoacoustic Probe Adapted from a Clinical Ultrasound System for Non-invasive Sentinel Lymph Node Imaging

Overview
Authors
Affiliations
Soon will be listed here.
Abstract

Clinical translation of photoacoustic (PA) imaging can be facilitated by integration with commercial ultrasound (US) scanners to enable dual-modality imaging. An array-based US scanner was modified for hand-held PA imaging. The performance was benchmarked in terms of signal-to-noise ratio (SNR), axial spatial resolution and sensitivity. PA images of a tube, filled with methylene blue (MB; approx. 30 mM) and placed at various depths in chicken tissue, were acquired. A 5 cm penetration depth was achieved with an 18.6 dB SNR using a laser fluence of 3 mJ cm(-2), only one-seventh of the safety limit (20 mJ cm(-2)). An axial resolution of approximately 400 μm was maintained at all imaging depths. The PA sensitivity to MB placed 2.3 cm deep in chicken tissue was less than 100 μM. Further, after intradermal injection of MB (approx. 30 mM), a rat sentinel lymph node was clearly identified in vivo, beneath a 3.8 cm thick layer of chicken breast. The accumulated concentration of MB in the node was estimated to be approximately 7 mM. The noise-equivalent sensitivities (approx. 2 cm depth) were 17 and 85 μM, ex vivo and in vivo, respectively. These results support the use of this PA system for non-invasive mapping and image-guided needle biopsy of sentinel nodes in breast cancer patients.

Citing Articles

Full-view volumetric photoacoustic imaging using a hemispheric transducer array combined with an acoustic reflector.

Sun M, Wang X, Wang Y, Meng Y, Gao D, Li C Biomed Opt Express. 2024; 15(12):6864-6876.

PMID: 39679402 PMC: 11640568. DOI: 10.1364/BOE.540392.


Tri-modality imaging for tumor detection with combined ultrasound, photoacoustic, and photoacoustic elastography.

Wang S, Huang B, Chan S, Tsang V, Wong T Photoacoustics. 2024; 38:100630.

PMID: 39040971 PMC: 11261081. DOI: 10.1016/j.pacs.2024.100630.


Azaphosphinate Dyes: A Low Molecular Weight Near-Infrared Scaffold for Development of Photoacoustic or Fluorescence Imaging Probes.

Yin R, Brondsted F, Li L, McAfee J, Fang Y, Sykes J Chemistry. 2024; 30(16):e202303331.

PMID: 38206848 PMC: 10957303. DOI: 10.1002/chem.202303331.


Review on ultrasound-guided photoacoustic imaging for complementary analyses of biological systems .

Lee H, Choi W, Kim C, Park B, Kim J Exp Biol Med (Maywood). 2023; 248(9):762-774.

PMID: 37452700 PMC: 10468641. DOI: 10.1177/15353702231181341.


Sentinel lymph node mapping in patients with breast cancer using a photoacoustic/ultrasound dual-modality imaging system with carbon nanoparticles as the contrast agent: a pilot study.

Gu L, Deng H, Bai Y, Gao J, Wang X, Yue T Biomed Opt Express. 2023; 14(3):1003-1014.

PMID: 36950229 PMC: 10026566. DOI: 10.1364/BOE.482126.


References
1.
Fronheiser M, Ermilov S, Brecht H, Conjusteau A, Su R, Mehta K . Real-time optoacoustic monitoring and three-dimensional mapping of a human arm vasculature. J Biomed Opt. 2010; 15(2):021305. PMC: 2859082. DOI: 10.1117/1.3370336. View

2.
Kim C, Cho E, Chen J, Song K, Au L, Favazza C . In vivo molecular photoacoustic tomography of melanomas targeted by bioconjugated gold nanocages. ACS Nano. 2010; 4(8):4559-64. PMC: 3065066. DOI: 10.1021/nn100736c. View

3.
Emelianov S, Li P, ODonnell M . Photoacoustics for molecular imaging and therapy. Phys Today. 2010; 62(8):34-39. PMC: 2879661. DOI: 10.1063/1.3141939. View

4.
Niederhauser J, Jaeger M, Lemor R, Weber P, Frenz M . Combined ultrasound and optoacoustic system for real-time high-contrast vascular imaging in vivo. IEEE Trans Med Imaging. 2005; 24(4):436-40. DOI: 10.1109/tmi.2004.843199. View

5.
Kim C, Erpelding T, Maslov K, Jankovic L, Akers W, Song L . Handheld array-based photoacoustic probe for guiding needle biopsy of sentinel lymph nodes. J Biomed Opt. 2010; 15(4):046010. PMC: 2937045. DOI: 10.1117/1.3469829. View