» Articles » PMID: 22005963

Forces Acting on the Anterior Meniscotibial Ligaments

Overview
Publisher Wiley
Date 2011 Oct 19
PMID 22005963
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The purpose of this study was to investigate the forces occurring in human anterior meniscotibial attachment structures under various loading conditions.

Methods: Twelve human knee joints were exposed to eight loading conditions (tibial rotations and varus/valgus stress) using a previously described knee joint simulator. Subsequently, the joints were axially compressed (1,000 N at 0° 30° and 60° knee flexion) using a materials testing machine. Then, we performed a tensile test to failure of the ligaments. Finally, we used the strains that occurred during the loading tests and the force-elongation diagrams obtained from the tensile test to recursively assess the resulting forces.

Results: In the anterior meniscotibial ligaments, we found maximum mean strains of 3.8 ± 2.3% under external moments and 1.5 ± 0.9% for axial compression. With an ultimate load of 454 ± 220 N for the anterolateral meniscotibial ligament and 397 ± 275 N for the anteromedial meniscotibial ligament, we estimated maximum forces of up to 50.2 N for the knee simulator tests and 22.6 N for the axial compression tests.

Conclusions: The low forces found in the meniscal ligaments suggest that for normal daily activities, meniscal replacement implants and allografts do not require a very rigid fixation at their bony insertions. However, it remains unknown, what level of force occurs in the meniscotibial ligaments under traumatic situations or impact knee loads. Furthermore, the results of the present study could help to optimize meniscal re-fixation and to improve the properties of meniscal replacement materials, such as tissue-engineered artificial menisci. Moreover, the results could be used for the validation of finite element models of the knee joint with the main focus on the meniscus and its biomechanical relevance for tibiofemoral contact pressure.

Citing Articles

Arthroscopic Centralization of the Medial Meniscus Reduces Load on a Posterior Root Repair Under Dynamic Varus Loading: A Biomechanical Investigation.

Deichsel A, Peez C, Raschke M, Geoff Richards R, Gueorguiev B, Zderic I Am J Sports Med. 2024; 52(12):3030-3038.

PMID: 39279271 PMC: 11494841. DOI: 10.1177/03635465241274791.


Medial Meniscotibial Ligament of the Knee: A Step by-Step Dissection.

Alencar Neto J, Cardoso A, Munhoz G, Neto L, Clazzer R, Ariel de Lima D Rev Bras Ortop (Sao Paulo). 2023; 58(5):e755-e759.

PMID: 37908524 PMC: 10615610. DOI: 10.1055/s-0043-1776137.


Anatomy of the Medial Meniscotibial Ligament of the Knee: A Systematic Review.

Alencar Neto J, Santos A, Lopes M, Lima L, Clazzer R, Ariel de Lima D Rev Bras Ortop (Sao Paulo). 2023; 58(2):206-210.

PMID: 37252293 PMC: 10212625. DOI: 10.1055/s-0042-1749199.


Rehabilitation following meniscal repair: a systematic review.

Spang Iii R, Nasr M, Mohamadi A, DeAngelis J, Nazarian A, Ramappa A BMJ Open Sport Exerc Med. 2018; 4(1):e000212.

PMID: 29682310 PMC: 5905745. DOI: 10.1136/bmjsem-2016-000212.


A model system for developing a tissue engineered meniscal enthesis.

McCorry M, Mansfield M, Sha X, Coppola D, Lee J, Bonassar L Acta Biomater. 2016; 56:110-117.

PMID: 27989921 PMC: 7326006. DOI: 10.1016/j.actbio.2016.10.040.


References
1.
Messner K, Verdonk R . It is necessary to anchor the meniscal transplants with bone plugs? A mini-battle. Scand J Med Sci Sports. 1999; 9(3):186-7. DOI: 10.1111/j.1600-0838.1999.tb00454.x. View

2.
Paletta Jr G, Manning T, Snell E, Parker R, Bergfeld J . The effect of allograft meniscal replacement on intraarticular contact area and pressures in the human knee. A biomechanical study. Am J Sports Med. 1997; 25(5):692-8. DOI: 10.1177/036354659702500519. View

3.
Iwaki H, Pinskerova V, Freeman M . Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee. J Bone Joint Surg Br. 2000; 82(8):1189-95. DOI: 10.1302/0301-620x.82b8.10717. View

4.
Goertzen D, Gillquist J, Messner K . Tensile strength of the tibial meniscal attachments in the rabbit. J Biomed Mater Res. 1996; 30(1):125-8. DOI: 10.1002/(SICI)1097-4636(199601)30:1<125::AID-JBM16>3.0.CO;2-N. View

5.
THOMPSON W, Thaete F, Fu F, Dye S . Tibial meniscal dynamics using three-dimensional reconstruction of magnetic resonance images. Am J Sports Med. 1991; 19(3):210-5; discussion 215-6. DOI: 10.1177/036354659101900302. View