Image-guided Radiotherapy Using Surgical Clips As Fiducial Markers After Prostatectomy: a Report of Total Setup Error, Required PTV Expansion, and Dosimetric Implications

Overview
Journal Radiother Oncol
Specialties Oncology
Radiology
Date 2011 Sep 6
PMID 21890224
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To determine the total setup error and the required planning target volume (PTV) margin for prostate bed without image guided radiotherapy (IGRT), and to demonstrate the feasibility and dosimetric benefit of IGRT post prostatectomy using surgical clips.

Materials And Methods: Seventeen patients were treated with intensity modulated radiotherapy (IMRT) to the prostate bed with a 1cm PTV margin. Three-dimensional shifts of the surgical clips inside the prostate bed were measured with respect to the isocenter from 364 orthogonal kV image pairs, and the total setup error was calculated to determine the required PTV margin. Alternative IMRT plans using 5mm or 1cm PTV expansion were generated and compared for rectal and bladder sparing.

Results: Surgical clips were reproducibly and reliably identified. The mean (standard deviation) shifts in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP), axes were: -0.1 mm (1.7 mm), 0.6 mm (2.4 mm), and -2.1 mm (2.6 mm), respectively. The required PTV margins were calculated to be 6, 8, and 9 mm in the LR, AP, and SI axis, respectively. A PTV expansion of 5mm, compared to 1cm, significantly reduced V65 Gy to the rectum by 10%.

Conclusions: In the absence of IGRT, a non-uniform PTV margin of 6mm LR, 8mm AP, and 9 mm SI should be considered. Use of clips as fiducial markers can decrease the total setup error, enable a smaller PTV margin, and improve rectal sparing.

Citing Articles

A systematic review of prostate bed motion and anisotropic margins in post-prostatectomy external beam radiotherapy.

Hodgins T, Forde E Tech Innov Patient Support Radiat Oncol. 2024; 32:100287.

PMID: 39555218 PMC: 11567049. DOI: 10.1016/j.tipsro.2024.100287.


Target coverage and organs at risk dose in hypofractionated salvage radiotherapy after prostatectomy.

Staal F, Janssen J, Krishnapillai S, Langendijk J, Both S, Brouwer C Phys Imaging Radiat Oncol. 2024; 31:100600.

PMID: 39022396 PMC: 11254181. DOI: 10.1016/j.phro.2024.100600.


The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy.

Chao M, Ho H, Joon D, Chan Y, Spencer S, Ng M Radiat Oncol J. 2019; 37(1):43-50.

PMID: 30947480 PMC: 6453813. DOI: 10.3857/roj.2018.00556.


Does Interfraction Cone Beam Computed Tomography Improve Target Localization in Prostate Bed Radiotherapy?.

Elakshar S, Tsui J, Kucharczyk M, Tomic N, Fawaz Z, Bahoric B Technol Cancer Res Treat. 2019; 18:1533033819831962.

PMID: 30782085 PMC: 6383090. DOI: 10.1177/1533033819831962.


Nonuniform Planning Target Volume Margins for Prostate Bed on the Basis of Surgical Clips on Daily Cone Beam Computed Tomography.

Song H, Salama J, Lee W, Wu Q Adv Radiat Oncol. 2019; 4(1):186-190.

PMID: 30706027 PMC: 6349621. DOI: 10.1016/j.adro.2018.09.014.