Fluoroscopic image technique, using either a single image or dual images, has been widely applied to measure in vivo human knee joint kinematics. However, few studies have compared the advantages of using single and dual fluoroscopic images. Furthermore, due to the size limitation of the image intensifiers, it is possible that only a portion of the knee joint could be captured by the fluoroscopy during dynamic knee joint motion. In this paper, we presented a systematic evaluation of an automatic 2D-3D image matching method in reproducing spatial knee joint positions using either single or dual fluoroscopic image techniques. The data indicated that for the femur and tibia, their spatial positions could be determined with an accuracy and precision less than 0.2 mm in translation and less than 0.4° in orientation when dual fluoroscopic images were used. Using single fluoroscopic images, the method could produce satisfactory accuracy in joint positions in the imaging plane (in average up to 0.5 mm in translation and 1.3° in rotation), but large variations along the out-plane direction (in average up to 4.0 mm in translation and 2.2° in rotation). The precision of using single fluoroscopic images to determine the actual knee positions was worse than its accuracy obtained. The data also indicated that when using dual fluoroscopic image technique, if the knee joint outlines in one image were incomplete by 80%, the algorithm could still reproduce the joint positions with high precisions.

Citing Articles

Acute effect of foot strike patterns on in vivo tibiotalar and subtalar joint kinematics during barefoot running.

Ye D, Li L, Zhang S, Xiao S, Sun X, Wang S J Sport Health Sci. 2023; 13(1):108-117.

PMID: 37220811 PMC: 10818114. DOI: 10.1016/j.jshs.2023.05.002.


Comparison of 3D Bone Position Estimation Using QR Code and Metal Bead Markers.

Ikumi A, Yoshii Y, Iwahashi Y, Sashida S, Shrestha P, Xie C Diagnostics (Basel). 2023; 13(6).

PMID: 36980448 PMC: 10047530. DOI: 10.3390/diagnostics13061141.


In Vivo Evaluation of the Position and Orientation of the Geometric Axis of the Tibiotalar Joint.

Yu J, Cao S, Wang C, Zhao D, Wang S, Zhang C Appl Bionics Biomech. 2023; 2023:2763099.

PMID: 36713625 PMC: 9876701. DOI: 10.1155/2023/2763099.


Multi-planar instability, laxity and reduced knee flexion during the support phase of walking are determinants of return to sports.

Zhou T, Xu Y, Zhou L, Wang S, Wang S, Xu W Front Bioeng Biotechnol. 2022; 10:1047135.

PMID: 36406209 PMC: 9669481. DOI: 10.3389/fbioe.2022.1047135.


An Experimental Study of a 3D Bone Position Estimation System Based on Fluoroscopic Images.

Yoshii Y, Iwahashi Y, Sashida S, Shrestha P, Shishido H, Kitahara I Diagnostics (Basel). 2022; 12(9).

PMID: 36140638 PMC: 9497817. DOI: 10.3390/diagnostics12092237.


References
1.
Kaptein B, Valstar E, Stoel B, Rozing P, Reiber J . A new model-based RSA method validated using CAD models and models from reversed engineering. J Biomech. 2003; 36(6):873-82. DOI: 10.1016/s0021-9290(03)00002-2. View

2.
Acker S, Li R, Murray H, St John P, Banks S, Mu S . Accuracy of single-plane fluoroscopy in determining relative position and orientation of total knee replacement components. J Biomech. 2010; 44(4):784-7. DOI: 10.1016/j.jbiomech.2010.10.033. View

3.
Mahfouz M, Hoff W, Komistek R, Dennis D . A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. IEEE Trans Med Imaging. 2003; 22(12):1561-74. DOI: 10.1109/TMI.2003.820027. View

4.
Hanson G, Suggs J, Freiberg A, Durbhakula S, Li G . Investigation of in vivo 6DOF total knee arthoplasty kinematics using a dual orthogonal fluoroscopic system. J Orthop Res. 2006; 24(5):974-81. DOI: 10.1002/jor.20141. View

5.
Tsai T, Lu T, Chen C, Kuo M, Hsu H . A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy. Med Phys. 2010; 37(3):1273-84. DOI: 10.1118/1.3301596. View